Intrinsically Safe Installation Requirements - Graco G3000 Instructions-Parts List Manual

Volumetric fluid flow meter. for precise metering of plural component fluids or solvents (depending on model). for professional use only.
Hide thumbs Also See for G3000:
Table of Contents

Advertisement

Installation
Intrinsically Safe Installation
Requirements
See F
. 2.
IG
1. The non-intrinsically safe terminals must not be con-
nected to any device which uses or generates more
than 250 Vrms or dc unless it has been determined
that the voltage has been adequately isolated.
2. The installation must meet the requirements of the
National Electric Code, Canadian Electrical Code
Part I, NFPA 70, Article 504 Resp., Article 505 and
ANSI/ISA 12.06.01.
3. Multiple earthing of components is allowed only if
high integrity equipotential system is realized
between the points of bonding.
4. Do not operate system with safety barrier cover
removed.
NON-HAZARDOUS LOCATION ONLY
System
250 VAC Maximum
Ground
Supply Voltage
NOTE: See Intrinsically Safe Installation Requirements above.
WARNING: Substitution of components may impair intrinsic safety. For installation,
maintenance or operation instructions, see instruction manual.
ADVERTISSEMENT: La substitution de composants peut compromettre la securite
intrinseque.
Intrinsically Safe Installation
F
. 2.
IG
8
ATEX CERTIFICATE #ITS12ATEX27565X
SYSTEM ASSEMBLY CERTIFICATE
Power 10-30 Vdc (Red), Ref. to Common
Common (Black)
Safety
Signal 0-30 Vdc (White), Ref. to Common
Barrier
Cable Shield
5. For ATEX, install per EN 60079-14 and applicable
local and national codes.
6. Cable used to connect sensor and safety barrier
must take capacitance and inductance into account.
The maximum capacitance of the barrier is to be
greater than the cable capacitance plus the sensor
capacitance (Ci). The maximum inductance of the
barrier is to be greater than the cable inductance
plus the sensor inductance (Li).
Find cable capacitance and inductance by:
a. Using the most exacting electrical parameters
provided by the cable manufacturer.
b. Using the electrical parameters determined by
measurement of a sample.
7. Product meets 500 Vac isolation test between the
intrinsically safe circuits and earth ground.
HAZARDOUS (CLASSIFIED) LOCATION
CLASS I, DIV I, GROUP D, T3 (US AND CANADA)
CLASS I, ZONE I GROUP IIA T3 (ATEX ONLY)
TA = 0°C TO 60°C
Sensor Entity Parameters
(per barrier channel):
Ui/Umax = 30 Vdc
Ii/Imax = 110 mA
Ci = 0.4 microFarads
Li = 0.01 mH
Pi = 0.8 W
Ground
(Grounded thru meter
mounting bracket to
system ground.)
Sensor - 24W650
24W651
Flow Meter Body
G3000
G3000HR
G250
G250HR
S3000
G3000A
24M600
Control Drawing
308778Y