INE-PHB-4
Portable pH Meter
Operation Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the INE-PHB-4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MRC INE-PHB-4

  • Page 1 INE-PHB-4 Portable pH Meter Operation Manual...
  • Page 2 2. Construction accurate measuring and extend the working life of the meter. Model INE-PHB-4 PH meter is a portable pH meter with 31/2 LCD 3. Operation display, displaying temperature and pH value simultaneously, 4.
  • Page 3 2.1 Normal operating conditions: 4. Operation (1) Ambient temperature: 5℃~35℃ The meter works on two pieces of 5V battery. Open the battery cover on the (2)Relative humidity: Not more than 80% backboard of the meter and insert the battery. (3)Temperature of measured solution: 5℃~60℃ Please calibrate before measuring pH value.
  • Page 4 4.5 Clean the electrode with distilled water, then put electrode into one of the When the temperature of the measured solution is much different from the three pH buffer solutions, the meter display mV value of the first point temperature of the buffering solution, the temperature of the meter must be buffer solution.
  • Page 5 5.7 Be sure to avoid strong and direct sunshine on the display for obtaining 5. Maintenance maximum life. Take care not to hit the display on any hard object, or touch In addition to the good construction of the meter, proper maintenance is also an the screen glass to avoid scratching.
  • Page 6 Model INE-PHB-4 operating flow diagram: Packing list INE-PHB-4 Turn ON The Meter Portable pH meter Displaying “MEAS” TO MV measurement Press “MODE” button Description Quant. Temperature Setting(“℃”is flashing) INE-PHB- 4 pH meter Press “▲” or “▼” button PH combination electrode Setting temperature Buffer pH4.7.9...
  • Page 7 pH Combination Electrode Instruction Manual One-in-two pH combination (polycarbonate) electrode  INE-65-1 Serials: Glass shell  INE-E-201 Serials:plastic  INE-E-202 Serials:Glass shell Characteristics shell One-in-three pH combination electrode...
  • Page 8: Troubleshooting

    with pH and temperature. 2. Insert the plug back into the filling (polycarbonate) shell, glass solution. Record value displayed  INE-E-301 Serials: plastic shell hole and put the electrode back to accessories and silicon rubber. of the meter. The sum of absolute (polycarbonate), box in ambient temperature.
  • Page 9 there is a plastic bottle which not calibrate pH value at 10 immerse the electrode in absolute solution (3.0mol/L) for 4 hours. contains KCl powder. Please add pH value at 25 . ethyl alcohol (or solution which 5. Adhered with greases: please appropriate deionized water in the can dissolve this organics) for 15 ...