  • Page 1 INSTRUCTION MANUAL NANOMAT 4...
  • Page 2: Table Of Contents

    Content Introduction ............................ 3 Parts supplied Nanomat 4 ......................3 Parts supplied Capillary Dispenser System .................. 3 Accessories / Consumables / Spare parts ................... 3 Unpacking/Installation ........................4 Nanomat 4 ..........................4 Capillary Dispenser System ......................4 Dispenser magazine ........................4 Getting started ..........................
  • Page 3: Introduction

    Introduction 1 Introduction The CAMAG Nanomat 4 serves for easy application of samples onto TLC and HPTLC plates or sheets, precisely positioned and without damage to the layer. The actual sample dosage is performed with disposable capillaries which are precisely guided by the Universal Capillary Holder.
  • Page 4: Unpacking/Installation

    Adjust the Y-coordinate for sample application (distance from lower edge of plate) (1) and tighten screw (2) • Place a marking strip (3) onto the base plate Fig.1: Setting up Nanomat 4 2.2 Capillary Dispenser System • Unpack the system and check the parts supplied.
  • Page 5: Getting Started

    Getting started • Unlock the feeder slide by lifting its end up. The capillaries are now pushed against the stop at the end • Now pull the adhesive strip off Fig.4-8: Setup of Dispenser Magazine 3 Getting started 3.1 Positioning a TLC-/HPTLC plate or sheet •...
  • Page 6: Sample Application

    Getting started • Push the Universal Capillary Holder into the dispenser opening until the magazine is flush with the end of the guide rail • Withdraw the capillary holder. It is now loaded with a capillary Fig.9: Capillary holder in the capillary dispenser 3.3 Sample application •...
  • Page 7: Maintenance

    49 30 516 55 50 · Fax 49 30 795 70 73 · E-Mail: infoberlin@camag.com CAMAG Scientific Inc. (USA) · 515 Cornelius Harnett Drive · Wilmington, NC 28401 Telephone 800 334 3909 · Fax 910 343 1834 · E-Mail: tlc@camag.com www.camag.com...
  • Page 9 Notes: __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________...