PR411DR type controller is single door access controller used in RACS 4 access control system. Both PR411DR and PR411DR-BRD versions are functionally identical, but differ mechanically. PR411DR is installed inside plastic enclosure fitted to mounting on DIN 35 mm rail, while PR411DR-BRD is just a PCB module without enclosure.
Fig. 4 PR411DR front panel 3.2.2 PR411DR-BRD controller According to fig. 5, PR411DR-BRD is equipped with 5 LED indicators and RESET button (S1) on its PCB. RESET button can be used to restart the controller in the same way as in case of powering device off and then on.
Fig. 5 LEDs at PR411DR-BRD controller PCB 3.3 Power supply Basically, PR411DR and PR411DR-BRD controllers are designed for power supply from 230VAC/18VAC transformer with minimal power output 25VA, but they can also be supplied with 12VDC or 24VDC. The connection of power supply is shown in fig. 6, fig.7 and fig. 8.
PR411DR Installation Guide Rev.K.doc 2016-10-28 Fig. 8 PR411DR controllers supplied with 12VDC General guidelines for 24VDC and 12VDC power supply Negative (GND) potentials of power supply units must be connected with any wire. It is not necessary to connect GND terminals of HRC series controllers.
3.6.1 PRT readers and XM-2 expander PR411DR controller can operate with two PRT series readers and XM-2 I/O expander – see fig. 10. Addresses of PRT readers must be ID=0 and ID=1 and the address of XM-2 expander must be ID=5.
Wiegand reader does not work properly with the controller, it might be necessary to use PR-GP module. The PR-GP works as electrical interface between reader and controller. In order to determine if PR-GP might be useful, please contact Roger technical support. Fig. 11 Connection of Wiegand readers 3.7 Input and output lines...
PR411DR Installation Guide Rev.K.doc 2016-10-28 3.6.1 Inputs All inputs (IN1..IN8) of controllers have identical electric structure and can be configured as NO or NC lines using PR Master software. The NO input is triggered by shorting it to supply minus (GND) while the NC input must be normally shorted to supply minus (GND) and it becomes triggered when connection with GND is interrupted.
Page 14
PR411DR Installation Guide Rev.K.doc 2016-10-28 During update of controller firmware by means of Roger ISP software (so called Fixed ID) Manually during Memory Reset procedure By means of PR Master software The first two methods enable configuration of hardware addresses while the remaining two enable configuration of software addresses.
PR411DR Installation Guide Rev.K.doc 2016-10-28 4.1.3 Addressing during Memory Reset procedure Software address can be configured during Memory Reset procedure – see 4.2 Memory Reset procedure. Note: Software address is effective only if the address set with jumpers on the controller is in range of 100..127 and FixedID is None.
4.4 Firmware update The latest versions of firmware and Roger ISP software are available at www.roger.pl. In order to update firmware it is necessary to connect the device by means of RS485 bus to communication interface (UT-2USB or RUD-1) and then connect the interface to PC with installed Roger ISP software.
PR411DR Installation Guide Rev.K.doc 2016-10-28 UT-4DR Ethernet-RS485 communication interface. UT-2USB USB-RS485 communication interface. RUD-1 Portable USB-RS485 communication interface with 12VDC/0.12A output. XM-2DR I/O expander. 6. P RODUCT HISTORY Table 7. Product history Product version Released Description PR411DR v.1.0 05/2011 The first commercial version of the product PR411DR v.1.1...