• Screen mode:
07:00
The screen can be displayed in standard mode or in
inverted mode.
Mon-Fri, Period 2
23.0°C
Figure 22
MONDAY 14:00
23.0°C

7.2.4 ENERGY MONITORING

You can display some statistics of the use of the NRG-DM.
In order to be able to do this, the currency, the load and the
cost of energy need to be filled in. In the energy monitoring
menu, you will find:
• Currency (what currency do you use)
• Load (how much electrical heating cable is installed in
this room in kW)
• Cost/unit (cost of 1 kWh)
In the energy monitoring menu, you will see the values
calculated for the last 2 days, for the last month & for the
last year.

7.3 ENGINEER SETTINGS

7.3.1 TEMPERATURE CALIBRATION

When running in Floor sensor mode (see 7.3.3 Sensor
setting)
You can calibrate the floor sensor to the actual floor
temperature by using the calibration menu. The floor
temperature can differ from temperature measured by the
floor sensor depending on the floor construction.
When running in Room sensor mode (see 7.3.3 Sensor
setting)
You can calibrate the ambient sensor to the actual room
temperature by using the calibration menu.
The NRG-DM is performing an auto calibration of the Room
Sensor after each factory reset (or after first installation).
The manual calibration of the Room sensor should only be
14
23.0°C
To
09:00
MONDAY 14:30
OK
MONDAY 14:22
23.0°C
OK
Menu
Standard
MONDAY 14:32
23.0°C
Menu
23.0°C
Menu
MONDAY 14:32
23.0°C
Menu
Inverted