9 TECHNICAL SPECIFICATION
Supply voltage
Power consumption in
Sleep mode
Power consumption in
Max. load
Main power switch
Relay output
Setpoint range
Ambient temperature
– transport
Protection class
Terminals
Floor sensor with 3 m
cable
Maximum length of
floor sensor cable
Dimension with frame
Color rounded front
Color square front
Color switch gear frame RAL 9010
Display
Control modes
Working modes
18
230VAC +/- 10%, 50Hz
400 mW
1000 mW
2-pole
230V, max. 13A
0°C to 40°C
-20°C to +70°C
IP21
2,5 mm
Screw cage clamp
2
12k @ 25°C +/- 0.75°C (no:38165)
100m, 2 x 1,5mm² (230VAC cable)
84 X 84 X 40mm
RAL 9010
RAL 9003
1.8'' Dot Matrix LCD display
(100 x 64 pixels) with blue
backlight
Floor Sensor (active when floor
sensor installed and connected)
Room Sensor with floor limiter
(active when floor sensor
installed and connected)
Room Sensor (active when no
floor sensor is connected)
No Sensor % regulator with
cycles of 20 minutes (active when
no floor sensor is connected)
Constant Mode, Event Mode,
Boost Mode