ELECTRICAL CONNECTION

NOTE:
All indoor units must be connected to the outdoor unit.
• Open the electric box cover (1), drag the communication wire from rubber plug A and fix them indivi-
dually with wire clamps.
• Prior to the wiring, please check the voltage marked on the nameplate and then carry out the wiring
following the wiring diagram.
• To prevent condensation, wrap insulating material around the electrical wire.
• Fix the wires with clamps after connection and fit them in the electric box.
• Put the 4-core cable through the hole of the chassis and the bottom of the appliance upward, and
then connect the power line and the communication line from the outdoor unit to the corresponding
terminals N(1), 2, 3 , and grounding terminal of the indoor unit. Wiring shall be done properly as per
the wiring diagram. (Note: Be sure the wring terminals A/B/C/D and piping joints A/B/C/D of the indoor
unit match with that of the outdoor unit respectively).
Electric box cover(1)
To indoor unit
Power supply 3 way
terminal board 4 core
rubber wire
To outdoor unit
Wire clamp
Cable-cross
loop
Cable-cross loop
Electric box cover(2)
Do seal here to prevent
water leakage from here