Ouellet FCD12KCHVS-I Owner's Manual

Ouellet FCD12KCHVS-I Owner's Manual

Floor or ceiling unit multizone heat pump inverter 9 000 to 24 000 btu/hr

Advertisement

Quick Links

Owner's Manual
FLOOR OR CEILING UNIT
MULTIZONE HEAT PUMP
INVERTER
9 000 to 24 000 BTU/hr
Models:
FCD09KCHVS-I
FCD12KCHVS-I
FCD18KCHVS-I
FCD24KCHVS-I
Please read this owner's manual carefully
before operating the unit and keep it for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FCD12KCHVS-I and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ouellet FCD12KCHVS-I

  • Page 1 Owner’s Manual FLOOR OR CEILING UNIT MULTIZONE HEAT PUMP INVERTER 9 000 to 24 000 BTU/hr Models: FCD09KCHVS-I FCD12KCHVS-I FCD18KCHVS-I FCD24KCHVS-I Please read this owner’s manual carefully before operating the unit and keep it for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Operation notices .................................3 Explanation of symbols ................................3 User notices....................................4 Precautions....................................4 Working temperature range ...............................6 Parts name ....................................7 Remote control ..................................8 User notice ....................................8 Buttons on remote control ..............................9 Icon identification on remote control display ......................9 Operation of remote control ............................
  • Page 3: Operation Notices

    OPERATION NOTICES EXPLANATION OF SYMBOLS Indicates a hazardous situation that, if not avoided, DANGER will result in serious injury or death. Indicates a hazardous situation that, if not avoided, WARNING could result in serious injury or death. Indicates a hazardous situation that, if not avoided, CAUTION may result in minor or moderate injury.
  • Page 4: User Notices

    USER NOTICES • The total capacity of the indoor units running at the same time cannot exceed 150% of the outdoor unit capacity. Otherwise, the cooling or heating effect of each indoor unit will be poor. • To ensure a successful startup, switch the main power on 8 hours before powering on the unit. •...
  • Page 5 • Do not repair the appliance by yourself. It may cause electric shock or damage. Please contact a qualified person when you need to repair it. • Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage. •...
  • Page 6: Working Temperature Range

    • The appliance shall be installed in accordance with national wiring regulations. • Installation must be performed in accordance with the requirement of NEC and CEC by a qualified person only. • The heat pump is a first class electric appliance. It must be properly grounded with specialized groun- ding device by a qualified person.
  • Page 7: Parts Name

    PARTS NAME Actual product may be different from below graphics, please refer to actual product NOTICE for reference purposes. Indoor unit Air outlet Guide louver Front panel Air filter, purifier (in air inlet grille) Air inlet Connecting pipe Remote Control...
  • Page 8: Remote Control

    REMOTE CONTROL USER NOTICES CAUTION • The distance between the remote control and receiving window should not be more than 26.25 ft. (8 m) and there should be no obstacle between them • The remote control should be placed 3.3 ft. (1 m) away from TV or Audio sets. •...
  • Page 9: Buttons On Remote Control

    BUTTONS ON REMOTE CONTROL No. Bouton Fonction ON/OFF Turn on or off the unit Set temperature and time Set fan speed MODE Set operation mode I FEEL Use of the remote control as ambient sensor Not available on models presented in this HEALTH manual Not available on models presented in this...
  • Page 10: Operation Of Remote Control

    OPERATION OF REMOTE CONTROL 1. ON/OFF button Pushing this button allows to turn on or off the device. When turning off the unit, the SLEEP function will be canceled but the pre-set time remains. 2. +/- button Push " + " or " - " button to decrease or increase temperature by one degree at a time. Temperature range is from 16 °C to 30 °C (61 °F to 86 °F).
  • Page 11 HEAT mode: When you select HEAT mode, device is working on heating mode. Press the " + " or " - " button to adjust temperature. NOTE: Cooling only unit can’t receive heating mode signal. 5. I FEEL button Press this button to activate I FEEL function and the icon " "...
  • Page 12 10. TIMER ON button and TIMER OFF button This timer function allows you to program the unit while determining when it starts and when it ends. Before using this function, make sure your unit is set on the right time. Setting the starting time of the device: 1.
  • Page 13: Special Functions

    14. SLEEP button SLEEP function is available in COOL (cooling), DRY (dehumidifer) and HEAT (heating) modes only. This function permits to gradually increase room temperature in COOL mode and to lower it in HEAT mode. You will then save energy without affecting your sleep. This function is settled over an 8-hour period.
  • Page 14: Preparation Before Installation

    PREPARATION BEFORE INSTALLATION OUTLINE DIMENSIONS OF INDOOR UNIT 225 mm 1220 mm 280 mm 1158 mm REQUIRED INSTALLATION CLEARANCE DISTANCES DIAGRAM >1500 mm POWER TIMER >600 mm >600 mm >1000 mm >300 mm >200 mm >1500 mm >600 mm >600 mm >2300 mm...
  • Page 15: Selection Of Installation Location

    SELECTION OF INSTALLATION LOCATION Basic requirements Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult a qualified person: • A place with strong heat sources, vapors, flammable or explosive gas or volatile objects spread in the air.
  • Page 16: Requirements For Electrical Connection

    REQUIREMENTS FOR ELECTRICAL CONNECTION Safety precautions • You must follow the electric safety regulations when installing the unit. • According to the local safety regulations, use qualified power supply circuit and circuit break. • Make sure the power supply matches with the requirement of the device. Unstable power supply or incorrect wiring may cause malfunction and damage the unit or fire hazard.
  • Page 17: Installation

    INSTALLATION INSTALLATION OF INDOOR UNIT Ceiling and floor mountings both have similar installation procedure as follows: Step 1: Determine the mounting position • Using the installation template, determine where the indoor frame will be installed. Installation template • Mark the pattern and remove the installation template. NOTE: Make sure that the drainage side is 10 mm lower than the other side in order to drain the condensate water easily.
  • Page 18 Step 3: Install drain pipe • Either the right rear or right side of the unit is suitable for fixing the drain pipe. • Insert the drain hose completely into the drain socket. • Add a clamp within the range of gray tape. Tighten until the screw head is less than 4 mm from the hose.
  • Page 19 Step 5: Connect the pipe of indoor unit Coat here with refrigeration oil • To prevent leakage, apply refrigeration oil on both inner and outer surfaces of the nut. Use refrigeration oil for R410A. • Aim the pipe joint at the corresponding bell mouth. •...
  • Page 20 Step 6: Make electrical connections • Open the front panel. • Remove the electrical box cover. • Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole upward. •...
  • Page 21 Step 8: Install the indoor unit Side panel fixing screw (M4) • Press the fixing knob of the air intake grilles. The grilles will open wider. • Pull the grilles from the indoor unit. • Loosen the side panel fixing screw and remove the side panel.
  • Page 22 • Lift the unit and slide it forward into place. Hanger bracket Hanger bracket setting bolt (M8) • Tightly screw both hanger bracket setting bolts (M8). Hanger bracket fixing • Tightly screw both hanger bracket fixing bolt (M6) bolts (M6) to prevent the displacement of the indoor unit.
  • Page 23: Malfunction

    MALFUNCTION MALFUNCTION ANALYSIS Please check below items before asking for servicing. If the malfunction still cannot be eliminated, please contact a qualified person. Phenomenon Items to check Solution Ask a qualified person to replace circuit Circuit break trips off? break. Is there a power failure? Wait until power resumes.
  • Page 24: Maintenance

    MAINTENANCE CLEANING AND MAINTENANCE WARNING • Turn off the unit and disconnect the power before cleaning to avoid electric shock. • Do not wash the unit with water to avoid electric shock. • Do not use volatile liquid or mineral oils to clean the unit. •...
  • Page 25: Cleaning The Filter

    CLEANING THE FILTER • Never dismantle the air filter except for cleaning; otherwise it may cause some error. • The filter should be cleaned every three months. If the unit operates in a highly dusty environment, cleaning frequency should be increased (generally once every two weeks). •...
  • Page 26: Operation Test

    OPERATION TEST 1. Before operation test • Ensure that the customer is satisfied. • Inform the customers about the important notes of the appliance. 2. Operation test • Put through the power, press the ON/OFF button on the remote control to start the unit. •...
  • Page 27 NOTES _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________...
  • Page 28 NOTES _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________...

This manual is also suitable for:

Fcd18kchvs-iFcd09kchvs-iFcd24kchvs-i

Table of Contents