Programming locations

Location 0 - event and time for output A. This location has two segments of numerical data. To
program the event and time set the following:
Segment 1. Select the event that triggers Output A. See Table 6 for events you can trigger.
Segment 2. Select how long an output will remain activated when an output triggers. For a location
that is programmed as zero, the output will follow the event.
Table 6.
Event and time programming for Output A
#
Event
0
Always on
1
AC fail (control or exp.)
2
Low battery (control or exp.)
3
Dynamic battery test time
4
Listen in
5
Line seizure
6
Telephone line fault
7
Program mode
8
Overcurrent (control or exp.)
9
Box tamper (control or exp.)
10
Siren tamper (control or exp.)
a.
Does not follow AC fail delay time.
b.
If set to the following condition, these events will be one second.
#
Event
11
Smoke power reset
a
12
Yelping siren
13
Steady siren
14
Any siren
15
Steady siren (temporal)
16
Any siren (temporal)
17
Alarm memory
18
Entry
19
Exit
20
Entry or exit
21
Armed
#
Event
22
Disarmed
23
Ready to arm
24
Not ready to arm
25
Fire
26
Fire trouble
27
Chime
28
Beeping keypad
29
Aux 1 keypad function
b
30
b
Aux 2 keypad function
31
Panic keypad function
b
32
b
Code entry (set in loc 8–17)
11