14
NX-320E Remote Power Supply
Installation Manual
Location 16 - codes 81 to 90, output enable. This location has 10 segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 16 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 81; Segment 10 corresponds to user 90. The
LEDs correspond to outputs A to C (see Table 8 on page 13.)
Location 17 - codes 91 to 99, output enable. This location has nine segments of feature selection data.
When you activate outputs with a user code (event #30), you can use Location 17 to restrict certain codes
from activating certain outputs. Segment 1 corresponds to user 91; Segment 9 corresponds to user 99. The
LEDs correspond to outputs A to C (see Table 8 on page 13).
Location 18 - A/C delay and dynamic battery test. This location has two segments of feature selection
data. Use this location to enable the A/C delay and the dynamic battery test, both of which are timed in
minutes. The factory default is 5-0, meaning the A/C power will be off for 5 minutes before a report is sent
or a Service light will illuminate, and the dynamic battery test is disabled (0 minutes). If you want the A/C
delay to be 8 minutes and the dynamic battery test to be 3 minutes, you would program 8, 3.
Location 19 - device options. This location has eight segments of feature selection data. Use this location
to enable various system features of the power supply module. The LEDs are described in Table 9.
Table 9.
Output enable
LED
1
2
3
4
5 to 8
Description
On for AC report always sent; Off follows control.
• If On, an AC fail report will be sent if power is lost for the time programmed in Location 18.
• If Off, the report will only be sent if the control panel has not sent an AC power lost report, and AC fail
report is enabled in Location 37 of the panel.
On for enables periodic battery test. Enables battery missing every 30 seconds.
On enables low battery reporting. If enabled, the power supply module will report a low battery warning
to the central station.
On enables siren tamper/trouble reporting. If enabled, the power supply module will report a siren tamper
to the central station.
Reserved.