Programming

You can use an LED keypad or LCD keypad to program the module.
Using an LED keypad
To program the module with an LED keypad, do the following:
1. Enter *, 8. All of the function key LEDs will begin to flash.
2. Enter the Go To Program code (default is 9713). If the code is valid, the Service LED will flash, and
the function LEDs will illuminate steadily, indicating you should enter the device to program.
3. To enter a module address, press 8, 6, # (See Table 4 on page 7). The Armed LED will illuminate while
it is waiting for a programming location to be entered.
4. Enter the programming location followed by the # key. The Armed LED will begin to flash. If this is a
valid location, the Armed LED will extinguish, the Ready LED will illuminate, and the binary data for
the first segment of this location will appear on the Zone LED.
5. To change the data, enter the data followed by the * key. The location will automatically increment to
the next segment. The data for that segment will display. Repeat the procedure until the system reaches
the last segment.
6. To exit this location without changing the data, press the # key.
7. To review the data, press the * key but do not enter the data. Each time you press *, the next segment
displays. After you program the last segment for a location, press * to exit that location. The system
will turn the Ready LED off and the Armed LED on. As before, you are now ready to enter another
programming location.
Note: If you attempt to program an invalid entry for a particular segment, the keypad sounder will emit a triple-beep and
remain in that segment until there is a valid entry.
8. To enter another location, do one of the following:
Enter the location number followed by the # key.
Press Police for the next location.
Press Fire for the previous location.
Press Auxiliary for the same location.
9. Press Exit to exit this module. Press Exit again, to completely exit program mode.