12
NX-320E Remote Power Supply
Installation Manual
Location 1 - special features for output A. This location has two segments of feature selection data to
program special features for output A (see Table 7)
Table 7.
Special features for output
Number
Segment 1 output
1
On for minutes; Off if output times in seconds.
2
On if latched until a code is entered; Off for timed.
3
On to stop time when a code is entered.
4
On for inverted output.
5
On to disable during listen-in (only events 12 to 16).
6
Reserved.
7
Reserved.
8
Reserved.
Location 2 - event and time for output B. This location has two segments of numerical data to program
the event and time for output B.
•
Segment 1. Select the event that triggers output B (See Table 6 on page 11).
•
Segment 2. Select how long an output will remain activated when an output triggers. For a
location that is programmed as zero, the output will follow the event.
Location 3 - special features for output B. This location has two segments of feature selection data to
program special features for output B (see Table 7).
Location 4 - event and time for output C. This location has two segments of numerical data to program
the event and time for output C.
•
Segment 1. Select the event that triggers output C. (See Table 6 on page 11).
•
Segment 2. Select how long an output will remain activated when an output triggers. For a
location that is programmed as zero, the output will follow the event.
Location 5 - special features for output C. This location has two segments of feature selection data to
program special features for output C (see Table 7).
Location 6 - event and time for the bell output. This location has two segments of numerical data to
program the event and time for the bell output.
•
Segment 1. Select the event that triggers the bell output. (See Table 6 on page 11).
•
Segment 2. Select how long an output will remain activated when an output triggers. For a
location that is programmed as zero, the output will follow the event.
Location 7 - special features for the bell output. This location has two segments of feature selection
data to program special features for the bell output (see Table 7).
.
Segment 2 event
On to activate when it occurs in Partition 1.
On to activate when it occurs in Partition 2.
On to activate when it occurs in Partition 3.
On to activate when it occurs in Partition 4.
On to activate when it occurs in Partition 5.
On to activate when it occurs in Partition 6.
On to activate when it occurs in Partition 7.
On to activate when it occurs in Partition 8.