Environmental conditions

Limit values for the standard version
Relative humidity for ambient temperature
40 °C
Ambient temperature
Installation altitude
Air with normal oxygen content, usually
The standard machines are not suitable for use in corrosive atmospheres, atmospheres with
a high salt content, or outdoor applications.
Limit values for the special versions
If the environmental conditions are different from the details listed here, then the values on
the rating plate or in the catalog will apply.
3.3.8

Optional built-on and built-in accessories

Machines can be equipped with the following integrated components/devices:
● Temperature sensors integrated in the stator winding in order to monitor the temperature
and protect the stator winding from overheating.
● Anti-condensation heating for machines whose windings are subject to a risk of
condensation due to the climatic conditions.
Machines can be equipped with the following mounted components/devices:
● Brake
● Rotary pulse encoder
● External fan (forced ventilation)
● Measuring nipple for SPM shock pulse measurement for bearing monitoring
Note
Further documents
Observe all of the other documents provided with this machine.
Supplementary devices
Depending on the order, various supplementary devices can be installed or mounted. These
include sensors for bearing temperature monitoring or winding monitoring, for example.
28
T
amb
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
Operating Instructions, 06/2018, A5E44455710A
Max. 55 %
-20 °C to +40 °C
≤ 1000 m
V
V
21 % (
/
)