Technical data
B.1 Tightening torques
B.1.2
Stud-type bushings
Table B- 2
Tightening torques for stud-type bushings
Thread ∅
Min.
Nm
Max.
B.1.3
Terminal boxes, end shields, grounding conductors, sheet metal fan covers
If no other tightening torques are specified, then the values in the following table apply.
Table B- 3
Tightening torques for screws on the terminal box, end shields, screw-type grounding conductor connections
Thread ∅
M 3.5
Nm
min
0.8
max
1.2
Tightening torque for the condensation drain plug
Tighten the condensation drain plug M6x0.75 with a torque between 1.5 and 2.0 Nm.
B.1.3.1
Terminal board and grounding
Table B- 4
Tightening torques for electrical connections on the terminal board and grounding
Thread ∅
M 3.5
min
0.8
Nm
Max.
1.2
B.1.4
Additional connecting terminals for monitoring equipment and anti-condensation
heating
Table B- 5
Main terminal box
EN 60999-1: 2000 table 4 III
Auxiliary terminal box
166
M 4
M 5
M 6
1
1.6
2.5
1.2
2
M 4
M 5
2
3.5
3
5
M 4
M 5
0.8
1.8
1.2
2.5
Tightening torques for monitoring equipment and anti-condensation heating
M 8
M 10
5
8
3
6
10
M 6
M 8
M 10
6
16
9
24
M 6
M 8
2.7
5.5
4
8
min 0.6 Nm
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
M 12
M 16
13
25
15.5
30
M 12
M 16
28
46
110
42
70
165
M 10
M 12
9
14
13
20
0.4 Nm
max 0.8 Nm
Operating Instructions, 06/2018, A5E44455710A
M 20
42
52
M20
225
340
M 16
27
40