SCN60
Service

Performance and Technical Specs

Overall:
Refrigerant: 4.5 oz R-134a
Compressor: Hermetic, 700 BTUH
Condenser: Forced draft
Fan blade: 3 blade, 6 inch
Evaporator: Stainless steel tube, copper coil
jacketed
Metering device: Cap tube
Auger drive: output speed 11 RPM
Water valve: Float in reservoir
Drain pump: Magnetic drive, controlled by
pressure switch
Bin control: Ultrasonic
Electrical Components:
Compressor - 2.9 to 3.1 amps
Fan motor
Auger motor, amp draw .4 to .5amp
Drain pump motor
Drain pump switch
Controller
Transformer
Water sensor
Ice level sensor
Membrane switch assembly
Control Timers
Power interruption, time to restart after power
restored: 2 minutes
Auger motor overload, time to restart: 4
minutes
Auger motor overload, restart window: 60
seconds
Auger motor low current, time to restart: 20
minutes
Auger motor low current, restart window: 60
seconds
Clean cycle time: 40 minutes total.
Note: During the auger motor restart window times,
there is no visible indication that the unit is in a
restart mode.
Light Blink Information
All blink once and repeat every 2 seconds:
Auger motor overload
All blink twice and repeat every 2 seconds:
Auger motor low current
All blink once and repeat every 10 seconds,
controller failure.
Water light blinks red: water supply failure
Controller Reset:
Cycle power off and on
Diagnostic Codes: No diagnostic codes are kept
Time to Clean indicator light standard interval to
switch light on is 6 months, it can be changed to
once per year or disabled.
To Adjust:
1. From Off, press and hold the On/Off and Clean
Reset Buttons for 5 seconds.
2. Press and Hold the Clean Reset Button for 5
seconds, then press On/Off. Then press On/off
again to cycle thru the settings:
Ice Making
6 months
On
1 year
Off
Disabled
Off
Light will automatically go out after a few seconds
of inactivity. Press Time To Clean to lock in the
new setting.
Quick reset of time to clean light: Press and hold
the Clean Reset button for 3 seconds.
May 2011
Page 7
Time to
Water
Clean
Off
Off
On
Off
Off
On