wtw FDO 70x IQ Series Operating Manual

wtw FDO 70x IQ Series Operating Manual

Optical iq sensor net d.o. sensors
Hide thumbs Also See for FDO 70x IQ Series:

Advertisement

Quick Links

ba75586e05
12/2011
®
FDO
70x IQ (SW)
®
FDO
700 IQ
®
FDO
701 IQ
®
FDO
700 IQ
®
FDO
701 IQ SW
Optical IQ S
ENSOR
Operating manual
N
D.O. sensors
ET

Advertisement

Table of Contents
loading

Summary of Contents for wtw FDO 70x IQ Series

  • Page 1 Operating manual ® 70x IQ (SW) ® 700 IQ ® 701 IQ ® 700 IQ ® 701 IQ SW Optical IQ S D.O. sensors ENSOR ba75586e05 12/2011...
  • Page 2 Copyright © 2016 Xylem Analytics Germany GmbH Printed in Germany.
  • Page 3: Table Of Contents

    ® 70x IQ (SW) Contents ® 70x IQ (SW) - Contents Overview ........1-1 How to use this component operating manual .
  • Page 4 ® Contents 70x IQ (SW) Technical data ....... 7-1 General measurement characteristics ....7-1 Application conditions .
  • Page 5: Overview

    ® 70x IQ (SW) Overview Overview How to use this component operating manual Structure of the IQ Sensor Net Operating Manual IQ S ENSOR operating manual System Operating Manual (Ring Binder) IQ Sensor MIQ Module MIQ Terminal Operating Operating Operating Manual Manual Manual...
  • Page 6: Models

    ® Overview 70x IQ (SW) Models ® The FDO 70x IQ (SW) consists of a sensor basis equipped with differ- ent sensor cap types, depending on the model: Sensor basis ® FDO 700 IQ Sensor cap: ® SC-FDO 700 ® SC-FDO 701 Sensor basis ®...
  • Page 7: Recommended Fields Of Application

    ® 70x IQ (SW) Overview Recommended fields of application Sensor model Recommended field of application. ® 700 IQ Stationary measurements in water/wastewa- ® 701 IQ ter applications. ® 700 IQ SW Stationary measurements in seawater, ® 701 IQ SW aquaculture. ®...
  • Page 8: Structure

    ® Overview 70x IQ (SW) Structure Structure ® Fig. 1-2 Structure of the D. O. sensor (example: FDO 70x IQ) Shaft Plug head connector Fixing ring Sensor membrane Sensor cap with memory chip Gold-plated contact pins for memory chip Measurement window Temperature sensor and locking device Sensor head Sensor cap with...
  • Page 9: Safety

    ® 70x IQ (SW) Safety Safety This component operating manual contains special instructions that ® must be followed during the operation of the FDO 70x IQ (SW) D.O. sensor. Thus, it is essential to read this component operating manual before carrying out any work using this sensor. In addition to this man- ual, the S chapter of the IQ S system operating man-...
  • Page 10: Authorized Use

    Protect the sensor, particularly against frost or overheating. CAUTION The sensor may only be opened by specialists authorized by WTW. The only exceptions to this are the activities described in chapter 5 M AINTENANCE CLEANING...
  • Page 11 ® 70x IQ (SW) Safety Safe operation If safe operation is no longer possible, the sensor must be taken out of operation and secured against inadvertent operation. Safe operation is no longer possible if the sensor:  has been damaged in transport ...
  • Page 12 ® Safety 70x IQ (SW) 2 - 4 ba75586e05 12/2011...
  • Page 13: Commissioning

    IQ SW. Information on this and other IQ S accessories is ENSOR given in the WTW catalog and on the Internet. Note How to connect the SACIQ (SW) sensor connection cable to the termi- nal strip of an MIQ module is described in chapter 3 I...
  • Page 14 Do not suspend the sensor on the sensor connection cable. Use a sen- sor holder or armature. Information on this and other IQ S ENSOR accessories is given in the WTW catalog and on the Internet. Connecting the sensor Take the protective caps off the plug connections of the sensor...
  • Page 15: Commissioning / Getting The Instrument Ready For Measuring

    ® 70x IQ (SW) Commissioning Commissioning / Getting the instrument ready for measuring Identification in the Both the sensor cap and sensor basis (sensor without cap) have a IQ S series number of their own. The sensor has to be equipped with a sen- ENSOR sor cap for a successful login to the IQ S .
  • Page 16: Fdo

    ® Commissioning 70x IQ (SW) ® 70x IQ (SW) setting table Setting Selection/values Explanation  Concentration Measuring mode Unit of the measured value on the measured value display.  Saturation  0 ... 20.00 mg/l Measuring range These measuring ranges are available for Concentration selection.
  • Page 17 ® 70x IQ (SW) Commissioning Setting Selection/values Explanation Temp. adjustment -1.5 K ... +1.5 K The temperature compensation enables the temperature display to be balanced (shifting of the zero point by ±1.5K). Notes:  Due to the thermal capacity of the sensor, it is necessary to place it in a container with at least 2 liters of water.
  • Page 18 ® Commissioning 70x IQ (SW) Note For information on oxygen measurement in solutions containing salt, see WTW application report no. 1193118. 3 - 6 ba75586e05 12/2011...
  • Page 19: Measuring / Operation

    ® 70x IQ (SW) Measuring / Operation Measuring / Operation Measuring WARNING Contact with the sample can be dangerous for the user! Depending on the type of sample, suitable protective measures must be taken (protective clothing, protective goggles, etc.). Note the data given in section 7.2 A , especially PPLICATION CONDITIONS the minimum immersion depth of the sensor (>...
  • Page 20: Function Check

    ® Measuring / Operation 70x IQ (SW) 2 cm  With air temperatures under 5 °C we recommend performing the function check and user calibration not in air but in air-saturated water that has a higher temperature. You obtain air-saturated water by pouring water several times in and out of two vessels so that it sparkles.
  • Page 21 ® 70x IQ (SW) Measuring / Operation Press The sensor starts the check. The display switches to the mea- sured value display. The CAL indicator flashes instead of the main measured value. At the same time, the momentary rela- tive slope flashes as the secondary measured value with the addition of TEST.
  • Page 22: User Calibration

    ® Measuring / Operation 70x IQ (SW) 4.2.3 User calibration Principle The user calibration can either be done in water vapor-saturated air or in air-saturated water (see C HECK OR CALIBRATION MEDIUM page 4-1). With the calibration procedure, the relative slope of the sen- sor is determined.
  • Page 23 ® 70x IQ (SW) Measuring / Operation Wait for the measured value to be largely stable (temperature adjustment). Switch off the maintenance condition. Canceling the user As long as the determination of the calibration data has not yet been calibration started (step 6), you can quit the calibration routine with The running determination of calibration data (after pressing in step...
  • Page 24: Calibration History

    ® Measuring / Operation 70x IQ (SW) 4.2.4 Calibration history Calibration history (available in the IQ S systems ENSOR 184 XT and 2020 XT Currently active only) calibration Chronological list of the last user cali- brations ® Fig. 4-1 Calibration historyFDO 70x IQ (SW) The calibration history contains the following information: Date...
  • Page 25: Reactivating Previous Calibration Data

    ® 70x IQ (SW) Measuring / Operation 4.2.5 Reactivating previous calibration data ® The FDO 70x IQ (SW) enables you to reactivate the last valid user calibration or the factory calibration. Thus you can immediately go on measuring if a calibration procedure failed or you suspect that the cali- bration conditions were not optimally met.
  • Page 26 ® Measuring / Operation 70x IQ (SW) 4 - 8 ba75586e05 12/2011...
  • Page 27: Maintenance, Cleaning, Replacement Parts

    ® 70x IQ (SW) Maintenance, cleaning, replacement parts Maintenance, cleaning, replacement parts General maintenance instructions WARNING Contact with the sample can be dangerous for the user! Depending on the type of sample, suitable protective measures must be taken (protective clothing, protective goggles, etc.). Maintenance condition We recommend to switch on the maintenance condition each time the sensor is taken out of the measuring position.
  • Page 28: Handling Of The Sensor Cap

    ® Maintenance, cleaning, replacement parts 70x IQ (SW) Handling of the sensor cap Despite its exterior robustness, the sensor is an optical high precision instrument. Therefore, special care should be taken when doing any maintenance or cleaning work:  Dirt and moisture under the sensor cap can affect the functioning and shorten the service life of the sensor cap.
  • Page 29: Cleaning The Sensor

    ® 70x IQ (SW) Maintenance, cleaning, replacement parts Mounting the sensor Check the front surface of the sensor for absolute cleanness and clean it if necessary (see section 5.4.1). Thoroughly clean the thread of the fixing ring. Place the new sensor cap on the sensor so that the tempera- ture sensor fits into the hole inside the sensor cap (see figure opposite).
  • Page 30: Interior Cleaning Of Sensor Cap And Sensor Head

    ® Maintenance, cleaning, replacement parts 70x IQ (SW) 5.4.2 Interior cleaning of sensor cap and sensor head If moisture or dirt have penetrated under the sensor cap, e.g. because the sensor cap is damaged, you can make the sensor ready for opera- tion again as follows: Caution Only use nonabrasive, alcohol-free detergents, as otherwise the...
  • Page 31: Replacement Parts And Accessories

    Air compressor to be triggered by Cleaning Air Box 480 019 relay, power supply 230 V AC - 230 VAC Note Information on further IQ S accessories is given in the WTW ENSOR catalog and on the Internet. ba75586e05 12/2011 5 - 5...
  • Page 32 ® Maintenance, cleaning, replacement parts 70x IQ (SW) 5 - 6 ba75586e05 12/2011...
  • Page 33: What To Do If

    ® 70x IQ (SW) What to do if... What to do if... Sensor does not appear Cause Remedy in the measured value – Sensor cap not mounted or – Sensor cap (see section 5.3) display and list of defective sensors –...
  • Page 34 ® What to do if... 70x IQ (SW) Measured value invalid Cause Remedy ( "----" displayed) – User calibration unsuccessful. – As a temporary measure to The sensor is blocked for mea- quickly restore the readiness surement. for service: Activate the fac- tory calibration (see section 4.2.5) –...
  • Page 35: Technical Data

    ® 70x IQ (SW) Technical data Technical data General measurement characteristics Note The measurement characteristics are primarily determined by the sen- sor cap type. The relevant data are given in the sections 7.5 and 7.6. Measuring principle Optical measurement based on photoluminescence. Measurement in water According to solubility function according to ISO 5814 Measurement in salt-...
  • Page 36: General Data

    ® Technical data 70x IQ (SW) General data FDO 70x IQ: Dimensions 40.0 39.7 Socket SACIQ... FDO 70x IQ SW: 39.7 59.5 Socket SACIQ... ® Weight (without sensor 70x IQ Approx. 900 g connection cable) ® 70x IQ SW Approx. 1500 g Connection technique Connection via SACIQ (SW) sensor connection cable Material...
  • Page 37: Electrical Data

    ® 70x IQ (SW) Technical data Automatic sensor Monitoring of the membrane function monitoring (SensCheck function) Instrument safety Applicable norms – EN 61010-1 – UL 3111-1 – CAN/CSA C22.2 No. 1010.1 Electrical data Nominal voltage Max. 24VDC via the IQ S (for more ENSOR details, see chapter T...
  • Page 38: Technical Data Of The Sc-Fdo ® 700

    ® Technical data 70x IQ (SW) ® Technical data of the SC-FDO Measuring ranges and D. O. partial pressure 0 ... 400 hPa resolutions Measuring Adjustable measuring range Resolution mode D. O. concentra- 0 ... 20.00 mg/L 0.01 mg/L tion 0 ...
  • Page 39 ® 70x IQ (SW) Technical data ® Technical data of the SC-FDO Measuring ranges and D. O. partial pressure 0 ... 400 hPa resolutions Measuring Adjustable measuring range Resolution mode D. O. concentra- 0 ... 20.00 mg/L 0.01 mg/L tion 0 ...
  • Page 40 ® Technical data 70x IQ (SW) 7 - 6 ba75586e05 12/2011...
  • Page 41: Indexes

    ® 70x IQ (SW) Indexes Indexes Explanation of the messages This chapter contains a list of all the message codes and related mes- sage texts that can occur in the log book of the IQ S system ENSOR ® for the FDO 70x IQ (SW) sensor.
  • Page 42 Operational voltage too low, no operation possible * Check installation and cable lengths, Follow installation instructions * Power unit(s) overloaded, add power unit(s) * Check terminal and module connections * Defective components, replace components ES133x Component hardware defective * Contact WTW 8 - 2 ba75586e05 12/2011...
  • Page 43: Info Messages

    ® 70x IQ (SW) Indexes 8.1.2 Info messages Message code Message text IC133x Sensor has been successfully calibrated * For calibration data, see calibration history IC333x Factory calibration has been activated. Make sure the sensor operates correctly. IC433x Last valid user calibration has been activated. Make sure the sensor operates correctly.
  • Page 44: Status Info

    ® Indexes 70x IQ (SW) Status info The status info is a coded piece of information on the current status of a sensor. Each sensor sends this status info to the controller. The sta- tus info of sensors consists of 32 bits, each of which can have the value 0 or 1.
  • Page 46 For more information on how Xylem can help you, go to xyleminc.com. ® Service address: Xylem Analytics Germany Sales GmbH & Co. KG Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany Tel.: +49 881 183-325 Fax: +49 881 183-414 E-Mail wtw.rma@xyleminc.com Internet: www.WTW.com Xylem Analytics Germany GmbH Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany...

This manual is also suitable for:

Fdo 700 iqFdo 700 iq swFdo 701 iqFdo 701 iq sw

Table of Contents