ADF Web HD67933-x-B2 User Manual

ADF Web HD67933-x-B2 User Manual

Modbus master / mqtt - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.001
English
Modbus Master / MQTT - Converter
(Order Code: HD67933-x-B2)
For Website information:
www.adfweb.com?Product=HD67933-B2
For Price information:
www.adfweb.com?Price=HD67933-2-B2
www.adfweb.com?Price=HD67933-4-B2
Benefits and Main Features:
Very easy to configure
Power Supply 18...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual Modbus Master / MQTT
Document code: MN67933_ENG
For others MQTT products, see also the following links:
Converter MQTT to
www.adfweb.com?Product=HD67930
www.adfweb.com?Product=HD67931
www.adfweb.com?Product=HD67932
www.adfweb.com?Product=HD67934
www.adfweb.com?Product=HD67935
www.adfweb.com?Product=HD67936
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
Revision 1.001
Page 1 of 36
(Ethernet)
(M-Bus)
(Serial)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67933-x-B2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67933-x-B2

  • Page 1 Revision 1.001 Page 1 of 36 Industrial Electronic Devices User Manual Revision 1.001 English Modbus Master / MQTT - Converter (Order Code: HD67933-x-B2) For Website information: www.adfweb.com?Product=HD67933-B2 For Price information: www.adfweb.com?Price=HD67933-2-B2 www.adfweb.com?Price=HD67933-4-B2 Benefits and Main Features: Very easy to configure Power Supply 18…35V DC and 8…24 V AC...
  • Page 2: Table Of Contents

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 2 of 36 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 3 of 36 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 4 of 36 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5: Connection Scheme

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 5 of 36 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67933-4-B2 ADFweb.com S.r.l.
  • Page 6: Characteristics

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 6 of 36 Industrial Electronic Devices CHARACTERISTICS: The HD67933-B2 is a Modbus Master / MQTT Converter. It allows the following characteristics: Electrical isolation between Ethernet and Modbus; Mountable on 35mm Rail DIN; Wide power supply input range: 18…35V DC and 8…24V AC;...
  • Page 7: Power Supply

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 7 of 36 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax...
  • Page 8: Function Modes

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 8 of 36 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9: Leds

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 9 of 36 Industrial Electronic Devices LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10: Rs485

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 10 of 36 Industrial Electronic Devices RS485: For terminate the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet). Here some codes of cables: Belden: p/n 8132 - 2x 28AWG stranded twisted pairs conductor + foil shield + braid shield;...
  • Page 11: Ethernet

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 11 of 36 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming the device and for MQTT communication. The Ethernet connection must be made using Connector2 of HD67933-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 12: Use Of Compositor Sw67933

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 12 of 36 Industrial Electronic Devices USE OF COMPOSITOR SW67933: To configure the Converter, use the available software that runs with Windows called SW67933. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Configuration / Open Configuration

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 13 of 36 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “Modbus Master / MQTT - Converter”...
  • Page 14: Software Options

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 14 of 36 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 15 of 36 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 16: Set Communication

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 16 of 36 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67933 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in different sections in order to define the different parameters of the converter: Working Mode...
  • Page 17 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 17 of 36 Industrial Electronic Devices ORKING This section is used to define the working mode of MQTT side of the converter. It is possible to define: Synchronous: it is possible to read/write the Modbus slaves device Figure 3b: “Set Communication ...
  • Page 18 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 18 of 36 Industrial Electronic Devices MQTT: This section is used to define the main parameters of MQTT line. The means of the fields are: In the field “Server URL”...
  • Page 19 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 19 of 36 Industrial Electronic Devices THERNET This section is used to define the general parameters of Ethernet. The means of the fields are: In the field “Ip Address”...
  • Page 20 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 20 of 36 Industrial Electronic Devices If the field “Enable DHCP” is checked, the converter acts as DHCP Server for the Clients connected. If the option is enabled, in the fields “DHCP First IP Address”...
  • Page 21 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 21 of 36 Industrial Electronic Devices TLS (T RANSPORT AYER ECURITY This section is used to define the parameters of TLS protocol. The means of the fields are: If the field “Enable TLS”...
  • Page 22: Mqtt Set Topic (Synchronous Mode)

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 22 of 36 Industrial Electronic Devices MQTT SET TOPIC (Synchronous Mode): By Pressing the “MQTT Set Topic” button from the main window for SW67933 (Fig. 2) the window “Set MQTT Topics” appears (Fig. 4). This section is used to define the MQTT topics where the converter will publish the data from Modbus and the topic that the converter will subscribes for writing the data to Modbus.
  • Page 23: Mqtt Set Topic (Asynchronous Mode)

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 23 of 36 Industrial Electronic Devices MQTT SET TOPIC (Asynchronous Mode): By Pressing the “MQTT Set Topic” button from the main window for SW67933 (Fig. 2) the window “Set MQTT Topics” appears (Fig. 4). This section is used to define the MQTT topics where the converter will publish the data from Modbus and the topic that the converter will subscribes for writing the data to Modbus.
  • Page 24 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 24 of 36 Industrial Electronic Devices MQTT S UBSCRIBE Figure 5b: “Set MQTT Topics MQTT Subscribe” window  The means of the fields are: In the field “Topic” the MQTT topic is defined; If the field “Retained”...
  • Page 25: Modbus Set Access (Synchronous Mode)

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 25 of 36 Industrial Electronic Devices MODBUS SET ACCESS (SYNCHRONOUS MODE): By pressing the “Modbus Set Access” button from the main window for SW67933 (Fig. 2) the window “Set Modbus Access” appears. This section is used to define the Modbus reading requests ODBUS The means of the fields are:...
  • Page 26: Modbus Set Access (Asynchronous Mode)

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 26 of 36 Industrial Electronic Devices MODBUS SET ACCESS (ASYNCHRONOUS MODE): By pressing the “Modbus Set Access” button from the main window for SW67933 (Fig. 2) the window “Set Modbus Access” appears. This window is divided in two parts, the "Modbus Read"...
  • Page 27 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 27 of 36 Industrial Electronic Devices ODBUS RITE The means of the fields are: If the field “Enable” is checked, the Modbus request is enabled; In the field “Slave ID”...
  • Page 28: Update Device

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 28 of 36 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 29 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 29 of 36 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67933 device. Warning: If Fig.
  • Page 30: Template String: Definition Of Mqtt Payload

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 30 of 36 Industrial Electronic Devices TEMPLATE STRING: DEFINITION OF MQTT PAYLOAD In the section “Set Communication” of the SW67933, if “Synchronous” mode is selected, it is possible to define a Template string for the MQTT messages.
  • Page 31 User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 31 of 36 Industrial Electronic Devices Example We have defined 3 rows in the “Modbus Set Access” table in this way: Row1: ID: 1, Type: Holding Register, Address: 100, NPoint: 2 Row2: ID: 2, Type: Coil Status, Address: 200, NPoint: 10 Row3: ID: 1, Type: Input register, Address: 300, NPoint: 1 We define a template string in this way:...
  • Page 32: Modbus Writing With Synchronous Mode

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 32 of 36 Industrial Electronic Devices MODBUS WRITING WITH SYNCHRONOUS MODE If “Synchronous” mode is selected, in order to send the Modbus writing requests it is necessary to use a specific MQTT payload. In this way, the converter can get all the info ned and compose the Modbus request.
  • Page 33: Mechanical Dimensions

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 33 of 36 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 10: Mechanical dimensions scheme for HD67933-4-B2 ADFweb.com S.r.l.
  • Page 34: Ordering Informations

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 34 of 36 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67933 – X – B 2 Connectors Type 2: Fixed Screw Terminal Enclosure Type B: Modulbox 4M, 35mm DIN Rail mounting...
  • Page 35: Disclaimer

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 35 of 36 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 36: Warranties And Technical Support

    User Manual Modbus Master / MQTT Document code: MN67933_ENG Revision 1.001 Page 36 of 36 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

Table of Contents