Normally Open Sensor Applications
1.. A.few.controllers.on.the.market.require.
normally.open.rain.sensors..To.attach.
the.receiver.to.this.type.of.controller,.
attach.the.blue.and.orange.wire.to.the.
sensor.input.
Controllers with 24 VAC solenoids and
a booster pump
1.. Locate.the.common.wire.to.the.solenoid.
valves.and.the.common.wire.to.the.pump.
relay..If.these.two.wires.are.connected.to.
the."common".terminal.on.the.controller,.
disconnect.both.of.them.
2.. Twist.together.these.wires.along.with.one.
of.the.wires.from.the.Wireless.Rain-Clik
and.secure.with.a.wire.nut.
3.. Attach.the.other.wire.from.the.
Wireless.Rain-Clik
"common".terminal.on.the.controller.
Pump
or
AC AC
MV
Line-In
Normally-
Open Relay
Line-Out (to Pump)
.
Note:
The.pump.circuit.output.must.be.
24.VAC..Do.not.proceed.if.115.VAC.
.receiver.to.the.
C
1
2
3
4
SENSOR BYPASS
SENSOR STATUS
RAIN SENSOR BYPASS
Y
Y
W
B
Solenoid
Valves
Common
Wire to All
Valves
Red light indicates
sensor is bypassed
GREEN = Sensor is dry
RED = Sensor is wet
Press to bypass, press
again to re-enable