Proactive thera3+ Instruction Manual

Proactive thera3+ Instruction Manual

3-in-1 physiotherapy device

Advertisement

Physiotherapy • Physiothérapie
Questions? Comments?
1-800-363-2381 • www.amgmedical.com
Instructions
A.M.G. Medical Inc.
Please read this manual thoroughly
Montréal, QC H4T 1V5 • 1-800-363-2381
before using this device for the first time.
West Chazy, NY 12992 • 1-888-412-4992

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the thera3+ and is the answer not in the manual?

Questions and answers

Sandra
February 8, 2025

how do I set the length of time for the treatment

1 comments:
Mr. Anderson
February 11, 2025

The treatment duration for the ProActive Thera3+ is preset to 30 minutes for all options. There is no mention of a manual adjustment for treatment duration in the provided information.

This answer is automatically generated

Summary of Contents for Proactive thera3+

  • Page 1 Physiotherapy • Physiothérapie Questions? Comments? 1-800-363-2381 • www.amgmedical.com Instructions A.M.G. Medical Inc. Please read this manual thoroughly Montréal, QC H4T 1V5 • 1-800-363-2381 before using this device for the first time. West Chazy, NY 12992 • 1-888-412-4992...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION..................4 • What is pain? • How does TENS work? • What is EMS and how does it work? SAFETY INFORMATION ................ 5 • Indications for use • Contraindications • Warning • Precautions • Adverse reactions DEVICE OVERVIEW ................
  • Page 3: Introduction

    INTRODUCTION SAFETY INFORMATION This device can be used for pain relief, muscle stimulation and 1. This device is recommended for: • Symptomatic relief of chronic massage. It provides two independent, controllable output channels. intractable pain, acute post traumatic pain or acute post surgical A pair of electrodes which can be connected to each output channel pain •...
  • Page 4: Precautions

    • Do not adjust controls while operating machinery or vehicles. • Turn the stimulator off before applying or removing electrodes. Channel 1 Channel 2 • Only use with ProActive lead wires and electrodes. lead wire lead wire • Long-term stimulation at the same electrode site may cause...
  • Page 5: Instructions For Use

    INSTRUCTIONS FOR USE Keys 1. Prepare the Unit Before use, charge Thera3+ with the enclosed USB cable. It can be plugged into a computer’s USB port or into a wall socket using a adaptor (not included). When battery is fully charged the LED indicator will change from yellow to green.
  • Page 6 Caution: 8. Adjust the intensity to start the treatment • Always wash and dry the treatment area before applying Press CH1+ or CH2+ to increase the intensity the electrodes. of the corresponding channel,which will begin • Do not turn the device on when the electrodes are not applied treatment.
  • Page 7: To Create A Customized Program

    PRESET PROGRAMS IN TENS MODE Notes: Note: Treatment length for all options below is 30 minutes. • The device will return to standby mode when you press or after 30 seconds of inactivity. • To clear the memory: Press and hold S for 3 seconds. The number of records in memory will flash on screen.
  • Page 8 Program 2 PRESET PROGRAMS IN EMS MODE Note: Treatment length for all options below is 30 minutes. Program Work Time Pulse Rate Pulse Width Waveform Wave Description Therapy Site (Min) (Hz) ( s) µ Program 1 Shoulder Synchronous Work time 13 sec (ramp up 1 sec.
  • Page 9 PRESET PROGRAMS IN EMS MODE MASSAGE PROGRAMS (PRESET ONLY) Note: Treatment length for all options below is 30 minutes. Note: Treatment length for all options below is 30 minutes. Program 1 U1 (Default) Program Work Time Pulse Rate Pulse Width Waveform Wave Description Phase Pulse Rate Pulse Width Work Time...
  • Page 10: Cleaning And Maintenance

    MASSAGE PROGRAMS (PRESET ONLY) - CONTINUED • Use the device only with the lead wires and electrodes provided Note: Treatment length for all options below is 30 minutes. or sold under the ProActive brand, following the placements Program 3 (Continued) and settings prescribed by your practitioner.
  • Page 11: Troubleshooting

    TROUBLESHOOTING If your device does not seem to be operating correctly, refer to the Problem Possible cause Solution chart below to determine what may be wrong. If none of these Stimulation Improper electrode Reposition electrode is ineffective placement measures correct the problem, the device should be serviced. Unknown Contact your doctor Problem...
  • Page 12: Warranty

    ELECTRODE PLACEMENT GUIDE LIMITED WARRANTY A.M G Medical Inc. warrants the device to be free from defects in Muscle Placement of Body Positionning and Voluntary Start of Group Electrodes the Contraction Phase material and workmanship for a period of one (1) year, to be proven by means of the sales receipt or invoice.
  • Page 13 ELECTRODE PLACEMENT GUIDE ELECTRODE PLACEMENT GUIDE Muscle Placement of Body Positionning and Voluntary Start of Muscle Placement of Body Positionning and Voluntary Start of Group Electrodes the Contraction Phase Group Electrodes the Contraction Phase Lower Back Sit. Important note: it is necessary Adductors Sit and place a rigid (but comfortable) object Muscles...
  • Page 14: Battery Replacement

    ELECTRODE PLACEMENT GUIDE ELECTRODE PLACEMENT GUIDE Muscle Placement of Body Positionning and Voluntary Start of Muscle Placement of Body Positionning and Voluntary Start of Group Electrodes the Contraction Phase Group Electrodes the Contraction Phase Deltoids Sit with your elbows placed inside armrests Hand Sit on a chair, with your forearm and the palm Extensors...