Operation Manual
FOR
®
Protekt
Aire 4000DX/5000DX
270 Washington Street,
Mount Vernon,
New York 10553
Phone# 1-855-BE-PROACTIVE (855-237-7622)
Fax# 845-205-6005
www.proactivemedical.com

Advertisement

Table of Contents
loading

Summary of Contents for Proactive Protekt Aire 4000DX

  • Page 1 Operation Manual ® Protekt Aire 4000DX/5000DX 270 Washington Street, Mount Vernon, New York 10553 Phone# 1-855-BE-PROACTIVE (855-237-7622) Fax# 845-205-6005 www.proactivemedical.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS IMPORTANT SAFEGUARDS................2 STATEMENTS....................2 INTRODUCTION....................3 PACKAGE CONTENTS..................4 PRODUCT FUNCTION..................5 Pump.......................5 Mattress......................5 SYSTEM INSTALLATION................6 OPERATION....................7-9 General......................7 CPR function....................9 Pressure set up....................9 Low pressure warning..................9 CLEANING......................10 ENVIRONMENT REQUIREMENTS...............11 HANDLING AND STORAGE................11 MAINTENANCE....................11 General......................11 Low pressure....................11 SPECIFICATIONS....................12 - 1 -...
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety present, basic safety precautions should always be followed, including the following: Danger To reduce the risk of electrocution: Always unplug this product immediately after use. Do not use while bathing. Do not place or store product where it can fall or be pulled into a tub or sink.
  • Page 4: Introduction

    INTRODUCTION This manual should be used for the initial set up of the system and for reference purposes. General The Protekt® Aire 4000DX/5000DX system is designed for prevention, treatment and management of pressure ulcers. The Protekt® Aire 4000DX/5000DX pump is a smart pump simple to operate and easy to use, constantly providing pressure redistribution and support to patients.
  • Page 5: Package Contents

    PACKAGE CONTENTS Check inside the package. If any of the following items should be missing or damaged, please contact your local dealer or service center for replacement immediately. Pump Unit Mattress Cover Sheet ❖ Optional The cover sheet makes cleaning an easy task. Manual Always read this manual before using this product.
  • Page 6: Product Function

    PRODUCT FUNCTION Pump Unit The functions of the pump for Protekt® Aire 4000DX/5000DX system are described below. ❖ Power Key(1) ➢ Press Power key on the panel, the pump will start/stop operation. ❖ Press Weight Range(2) ➢ Press up or down buttons to select the correct patient weight. ❖...
  • Page 7: System Installation

    Pump Unit Activation SYSTEM INSTALLATION a) Position Control Unit by hanging hooks over foot The following describes the procedures for board of the bed or place unit on the floor under the setting up the system for the first time. bed.
  • Page 8: Operation

    OPERATION NOTE: Always read the operating instructions before use. General This product is designed to provide maximum comfort to patients. Make sure that you operate this product in a proper way optimizing its value. Here we provide some general information that you should be aware of.
  • Page 9 NOTE: Please follow instructions below for detailed operating procedure of each type. Step 1 Turn on the power. The indicator of the power key will flash. Step 2 The pump will enter into static mode when the power is initially turned on. First it will inflate the mattress to 15mmHg, and then enter alternate mode and indicator of the power key remains on.
  • Page 10: Cpr Function

    CPR function When there is an emergency requirement to perform CPR on the patient, pull the CPR strap at the head section of the mattress to release the air quickly from the mattress. The CPR straps are located at the front right-hand side of the mattress. Weight/Pressure set up Users can adjust air mattress to a desired firmness according to patient’s weight or the suggestion from a health care professional.
  • Page 11: Cleaning

    CLEANING In this section, we describe the procedures to clean and decontaminate the pump. It is important to follow these procedures before using the system again. The cleaning task is required at least once a week to maintain personal hygiene. Pump Unit DO NOT immerse or soak the pump in any water or fluids.
  • Page 12: Environment Requirements

    ENVIRONMENT REQUIREMENTS Operating Conditions Ambient Temperature: 41°F~104°F Relative Humidity: 15%~90%, non-condensing Atmospheric pressure: 700hPa to 1060hPa Storage and shipping conditions Ambient temperature: -13°F~158°F Relative Humidity: 10%~90%, non-condensing Atmospheric pressure: 700hPa to 1060hPa HANDLING AND STORAGE Lay the mattress out flat and upside down. Roll from the foot end towards the head end;...
  • Page 13: Specifications

    Mattress Item: Protekt® Aire 4000DX/5000DX Item: Protekt® Aire 4000DX/5000DX Power supply: 120V/50Hz, 1A Protekt Aire 4000DX: 80’’(L) x 36’’(W) x 8’’(H)- 8" Cells Protekt Aire 5000DX: 80’’(L) x 36’’(W) x 8’’(H)- 5’’ Cells, 3’’ foam base Air output: 8 liter/min.

This manual is also suitable for:

Protekt aire 5000dx