CTC Union GS 6-8 Installation And Maintenance Manual
CTC Union GS 6-8 Installation And Maintenance Manual

CTC Union GS 6-8 Installation And Maintenance Manual

Ground source heat pump

Advertisement

Quick Links

End customer overview
CTC GS 6-8
Ground source heat pump
1. Sign the installation checklist.
2. Serial no. behind touchscreen.
3. Bleed radiator system and products,
approx. one month after installation + at least
once per year.
4. Screw in/close the bleed screw on the au-
tomatic bleeder approx. three months after
installation.
5. Fit/turn the safety valve,
approx. four times per year.
6. Check the system pressure regularly and ask
the installer what system pressure your system
The system pressure must be
should have.
set 0.3 bar higher than the pre-pressure in
the expansion tank.
7. dirt filter for
tap water
Read the full instructions in the Installation and
Maintenance Manual
7. Regularly clean the dirt filter (close off incoming
tap water; remove and clean the filter)/solenoid
filter ball valve (close off the flow to the heat
pump; remove and clean the filter).
8. Set the correct heating curve for a comfortable
room temperature; check that the thermostat
valves on the element or floor heating are set
up correctly. These may need to be opened.
9. Set the hot water mode according to your
requirements.
3. & 5. safety valve
7. solenoid
filter ball valve
162 205 98-1
2018-09-26
4. automatic bleeder
6. manometer
2. serial number for registration
behind screen which can be
tilted
8 & 9. touchscreen
CTC GS 6-8
1

Advertisement

Table of Contents
loading

Summary of Contents for CTC Union GS 6-8

  • Page 1 162 205 98-1 2018-09-26 End customer overview CTC GS 6-8 Ground source heat pump 1. Sign the installation checklist. 7. Regularly clean the dirt filter (close off incoming tap water; remove and clean the filter)/solenoid 2. Serial no. behind touchscreen.
  • Page 2 With the heat pump connected, the immersion heater works to provide additional heat as needed only. The touchscreen can be used to set whether the immersion heater goes in and with how much power. CTC GS 6-8...
  • Page 3 Options with CTC GS 6-8 * In addition to the basic installation, accessories are required such as: Extra sensor, mixing valve group 2, expansion card etc. Volume tank CTC VT 80 may be required for some houses (see installation manual for more information).
  • Page 4: Home Screen

    Reset alarm support in the event of a fault report. See troubleshooting chart at the very Serial number back of the installation manual. XXXX-XXXX-XXXX Call your installation engineer in the first article group–year/week–sequential number instance CTC GS 6-8...
  • Page 5 Change: Select: Hot Add heat DHW – Yes water tank Installer “Installer” is used by the installer to configure the settings and servicing for your heating system. More settings and tips in the installation and service manual CTC GS 6-8...
  • Page 6: Heat Settings

    Normal temperature system (factory setting) inclination = 50 High temperature system (older houses, small radiators, poorly insulated) inclination = 60 Example in image: 1. Inclination 50, Adjustment 0° 2. Inclination 40, Adjustment 0° 3. Inclination 50, Adjustment 5° CTC GS 6-8...
  • Page 7: Energy Consumption

    • Clean any dirt filters regularly; a deterioration in water flow can increase the electricity used by the circulation pump. • Make sure the speed of the charge/circulation pump provides the right flow (see the chapter “System adjustments” in the Installation and Maintenance Manual). CTC GS 6-8...
  • Page 8 Checklist The checklist must always be completed by the installation engineer • In the event of a service, this information may be called for. • Installation must always be carried out according to the installation and maintenance instructions. • Installation must always be carried out in accordance with best professional practice. •...