Technical Specifications - Royal Sovereign ARP-51400HA Owner's Manual

Hide thumbs Also See for ARP-51400HA:
Table of Contents

Advertisement

Available languages

Available languages

Problem
unit does not start
Room∙temperature∙is∙lower∙than∙the∙setting∙temperature.∙(Cooling∙
when pressing power
mode)∙
button
The doors or windows are not closed.
There are heat sources inside the room.
Not cool enough
Exhaust air hose is not connected or blocked.
Temperature setting is too high.
Air inlet is blocked.
The ground is not level or not flat enough.
noisy
The sound comes from the flowing of the refrigerant inside the air conditioner. It is normal.
e0/e3
Electrical short on both temperature sensor and PCB
e2/e4
Indicates water tank full or possibly the incorrect wiring of plug

tecHnIcal SpecIfIcatIonS

Figures∙noted∙in∙the∙contents∙are∙for∙reference∙only;∙variation∙may∙result∙due∙to∙the∙application∙in∙different∙countries∙or∙regions,∙and∙shall∙be∙based∙on∙practical∙operation.
Description of Product
Cooling∙capacity∙(Btu)
Voltage∙/Frequency
Operating Sound Level
Possible
Input Power
Timer
Coolant
Dimensions
Weight
Reset the temperature.
Position the air exhaust hose correctly, keeping it as short and free of
curves as possible to avoid bottlenecks
check and remove any obstacles obstructing air discharge.
Connect or clean the exhaust air hose.
Reset the temperature.
Clean the air inlet.
Place the unit on a flat, level ground if possible
Contact an electrician for repair
Please User needs to pull out the rubber stopper which is located at the bottom
of the unit to drain the water away. Check that the plug has been wired correctly
aRp-51400Ha
115∙V∙/∙60∙Hz
13.8" x 21.1" x 23.6"/ 35.1cm x 53.6cm x 60 cm
60.0 lbs/27.2 kg
15
ARP-51400HA
Suggested Remedies
14000 BTU
1340 W
65 dB
24 hours
R410 A

Advertisement

Chapters

Table of Contents
loading

Table of Contents