Summary of Contents for Royal Sovereign ARP-1000EX

  • Page 1 OWNER’S MANUAL ARP-900EX / 1000EX / 1200EX PORTABLE AIR CONDITIONER ARP-900EX / 1000EX / 1200EX PORTABLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTÁTIL Read and retain these instructions for future reference Royal Centurian Inc.
  • Page 2 PORTABLE AIR CONDITIONER Model ARP-900EX / 1000EX / 1200EX...
  • Page 3 PARTS Front 1. Control Panel 2. Cooling Air Outlet 3. Remote Signal Receiver 4. Handle Accessories 10. Extendable window spacer - To fill extra space in window (1) 11. Exhaust hose/Inlet hose- (2) 12. Hose adapter- For insertion over each end of hose (4) 13.
  • Page 4: Safety Precautions

    SAFETY PRECAUTIONS 1.Only use in the upright position on a flat, level surface at least 20"/50cm from any object. 2.WARNING- Please read the warning label on the power cord before handling the unit. 3.Do not place objects on top or in front of the unit. 4.Closely supervise children and pets while unit is in use.
  • Page 5: Installation

    INSTALLATION 1. Connect one hose adapter to each end of the 2 hoses. 2. Insert one hose into the exhaust air outlet and one hose into the air inlet. 3. Insert the window spacer into the window. 4. Mount the window spacer connector covering the holes on the extendable window spacer.
  • Page 6: Operation Functions

    OPERATION/FUNCTIONS Control panel 1. Water full indicator light 2. Cool indicator light 3. Dehumidify indicator light 4. Fan indicator light 5. Power button 6. Mode button (Cool, Dehumidify, Fan) 7. Speed button (High, Medium, Low) 8. High indicator light 9. Medium indicator light 10.
  • Page 7 SPEED Press the SPEED button to select a High, Medium or Low setting. TIMER (1-12 Hours) The timer button will allow you to turn the unit ON or OFF without even being in the room. If the unit is OFF- Press the TIMER button on the control panel or remote control (Timer indicator light will be lit).
  • Page 8 ARP-900EX / 1000EX / 1200EX REMOTE CONTROL LCD Display Power button Temperature/Timer UP Button Temperature/Timer DOWN button Mode button (Cool, Dehumidify, Fan) Timer button Speed button (High, Medium, Low) Fahrenheit/Celsius button...
  • Page 9: Maintenance

    MAINTENANCE Always unplug the air conditioner from the outlet before cleaning. To maximize the efficiency of the air conditioner, clean regularly. Cleaning the Filte Remove the filter from the back of the unit. Use a vacuum cleaner or gently tap the filter to remove loose dust and dirt, then rinse thoroughly under warm running water.
  • Page 10: Troubleshooting

    TROUBLE SHOOTING Problem The air conditioner does not run The machine is not cooling very well The unit is vibrating Sudden noise * NOTE: Never try to repair or dismantle the unit yourself. ARP-900EX / 1000EX / 1200EX Possible Cause/Solution Check to see if it is plugged in.
  • Page 11 Recommended room size Power supply Compressor Refrigerant Fan speed Timer Thermostat Unit weight Unit dimension Carton dimension ARP-900EX ARP-1000EX 9000 10000 950W / 8.7A 950W / 8.7A 1.6 L/h 1.6 L/h 300 sq. ft. 350~400 sq. ft. 115V/60Hz/1 phase Rotary 1-12 hours 61°F-89°F...
  • Page 12: Full One Year Warranty

    This warranty is in lieu of any and all expressed warranties. In no even shall Royal Sovereign be liable for consequential or incidental damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
  • Page 13: Manual Del Propietario

    Spanish MANUAL DEL PROPIETARIO ARP-900EX / 1000EX / 1200EX ACONDICIONADOR DE AIRE PORTÁTIL ARP-900EX / 1000EX / 1200 EX PORTABLE AIR CONDITIONER ACONDICIONADOR DE AIRE PORTÁTIL Lea y tenga presente estas instrucciones para futuras consultas Royal Centurian Inc.
  • Page 14 ACONDICIONADOR DE AIRE PORTÁTIL Modelo ARP-900EX / 1000EX / 1200EX...
  • Page 15 PARTS Front 1. Panel de control 2. Salida de aire de enfriamiento 3. Receptor de la señal remota 4. Manilla Accesorios 10. Separador de la ventana extensible: Para rellenar el espacio sobrante en la ventana (1) 11. Manguera de escape/Manguera de entrada (2) 12.
  • Page 16: Precauciones De Seguridad

    PRECAUCIONES DE SEGURIDAD 1. Use la unidad sólo en su posición vertical sobre una superficie plana y nivelada, a una distancia mínima de 20 pulg./50 cm de cualquier objeto. 2. ADVERTENCIA: Lea la etiqueta de advertencia en el cable de alimentación antes de operar la unidad. 3.
  • Page 17: Instalación

    INSTALACIÓN 1. Conecte un adaptador de manguera a cada extremo de las 2 mangueras. 2. Inserte una manguera en la salida de aire de extracción y otra en la entrada de aire. 3. Inserte el separador en la ventana. 4. Monte el conector del separador de la ventana cubriendo los orificios del separador de la ventana extensible.
  • Page 18 OPERACIÓN/FUNCIONES PANEL DE CONTROL 1. Luz indicadora de tanque lleno de agua 2. Luz indicadora Cool 3. Luz indicadora Dehumidify 4. Luz indicadora Fan 5. Botón de encendido 6. Botón Mode (Cool, Dehumidify, Fan) 7. Botón de velocidad (High, Medium, Low) 8.
  • Page 19 VELOCIDAD Presione el botón de VELOCIDAD para seleccionar un ajuste High, Medium o Low. TEMPORIZADOR (1 a 12 horas) El botón del temporizador le permite ENCENDER o APAGAR la unidad sin siquiera encontrarse en la habitación. Si la unidad está APAGADA : Presione el botón TIMER (TEMPORIZADOR) en el panel de control o el control remoto (se encenderá...
  • Page 20 ARP-900EX / 1000EX / 1200EX CONTROL REMOTO Pantalla de LCD Botón de encendido Botón para AUMENTAR la temperature/el temporizador Botón para REDUCIR la temperature/el temporizador Botón Mode (Cool, Dehumidify, Low) Botón del temporizador Botón de velocidad (High, Medium, Low) Botón Fahrenheit/Centígrado...
  • Page 21: Mantenimiento

    MANTENIMIENTO Siempre desenchufe el acondicionador de aire del tomacorriente antes de limpiarlo. Para obtener el máximo rendimiento del acondicionador de aire, límpielo con frecuencia. Limpieza del filtro Quite el filtro de la parte trasera de la unidad. Limpie el filtro con una aspiradora o dele golpes suaves a fin de eliminar el polvo y suciedad sueltos;...
  • Page 22: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS Problema El acondicionador de aire no funciona. La unidad no enfría adecuadamente. La unidad vibra. Se produce ruido repentino. * NOTE: Nunca intente reparar ni desmontar la unidad por su cuenta. ARP-900EX / 1000EX / 1200EX Posible causa o solución Verifique que esté...
  • Page 23: Especificaciones

    Compresor Refrigerante Velocidad del ventilador Temporizador Termostato Peso de la unidad Dimensiones de la unidad Dimensiones de la caja ARP-900EX ARP-1000EX 9000 10000 950W / 8.7A 950W / 8.7A 1.6 L/h 1.6 L/h 300 pies 350~400 pies 115 V/60 Hz/monofásico...
  • Page 24 Royal Sovereign. Esta garantía está en vigencia para el comprador original por un período de un año, a partir de la fecha de compra, y es intransferible.

This manual is also suitable for:

Arp-1200exArp-900ex