HSNRQ70B
This appliance shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements
This appliance must be installed, maintained and removed only by an Authorised Person.
For continued safety of this appliance it must be installed and maintained in
accordance with the manufacturers instructions.
Operation Manual
Split Type Wall Mounted Air Conditioner
Rinnai Systems Models
Indoor
HINRQ25B
HINRQ35B
HINRQ50B
HINRQ70B
Outdoor
HONRQ25B
HONRQ35B
HONRQ50B
HONRQ70B
REFRIGERANT
R32

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai HSNRQ25B

  • Page 1 Operation Manual Split Type Wall Mounted Air Conditioner Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B HSNRQ35B HINRQ35B HONRQ35B HSNRQ50B HINRQ50B HONRQ50B HSNRQ70B HINRQ70B HONRQ70B This appliance shall be installed in accordance with: REFRIGERANT • Manufacturer’s Installation Instructions • Current AS/NZS 3000 •...
  • Page 2 This page is intentionally blank Rinnai Split AC OM...
  • Page 3: Table Of Contents

    Service Maintenance Schedule - Non Ducted Air Conditioning Systems ��������������������������������������������������������� 16 General Maintenance ��������������������������������������������������������������������������������������������������������������������������������������� 17 Cleaning The Air Filter �������������������������������������������������������������������������������������������������������������������������������������� 17 Save A Service Call ������������������������������������������������������������������������������������������������������������������������������������������ 18 When to Call for Service ����������������������������������������������������������������������������������������������������������������������������������� 18 Warranty Contacts Rinnai Split AC OM...
  • Page 4: Warnings And Important Information

    Read the OPERATING INSTRUCTIONS carefully before operation. Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation. Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like. Rinnai Split AC OM...
  • Page 5 The table below indicates the temperature ranges the air conditioner can be operated within. MODE Cool Mode Heat Mode Dry Mode Room Temperature > 17°C < 27°C > 17°C Outdoor Temperature -7°C ~ 52°C -7°C ~ 24°C -7°C ~ 52°C Rinnai Split AC OM...
  • Page 6: Air Conditioner Basics

    The remote control may operate other electronic devices if pointed towards them. Make sure to point the remote control towards the signal receiver of the air conditioner. NOTE For proper operation, use a soft cloth to clean the signal transmitter LED and the receiver window. Rinnai Split AC OM...
  • Page 7: Remote Control Layout

    ROOM° C used for an extended period of time. 18� SPOT SWING button DISPLAY CLEAN FRESH Sets a fixed direction for air flow horizontally. SPOT 19� ECO button SWING Sets appliance to the most efficient operation. 20� Wireless Transmitter LED 21� LCD screen Advanced Displays settings and operation modes� Operation 22� Blank buttons Buttons Not used� Rinnai Split AC OM...
  • Page 8: Basic Operation

    The fan speed can be adjusted manually or set to automatic� 1� Press  the  "FAN"  button  until  the  desired  fan  speed  is  shown  on  the  LCD  AUTO screen (displayed below the temperature display), the available fan speeds  SPEED SPEED are AUTO / low (2 bars) / medium (4 bars) / high (6 bars). Medium Select "AUTO" if you wish the fan speed to be adjusted automatically by the  High Auto appliance� Rinnai Split AC OM...
  • Page 9: Adjusting Vertical Air Flow

    When cycling, "SWING ↔ "  and the swing icon are shown on  the LCD screen� DO NOT attempt to adjust the air deflector vanes manually as this can result in damage to the louvre movement mechanisms. CAUTION Rinnai Split AC OM...
  • Page 10: Advanced Operation

    Press the "ON/OFF" button to turn on appliance� AUTO SPEED 2� Press the "MODE" button until "FAN" is shown on the LCD screen. 3� Press the "SPEED" button until the desired speed is shown on the LCD screen  Medium (the available fan speeds are low (2 bars) / medium (4 bars) / high (6 bars). High In this mode, Swing operations for air direction can still be adjusted, however the AUTO setting for the fan speed is not available. NOTE Rinnai Split AC OM...
  • Page 11: Turbo

    Attempting to alter the fan speed during Quiet mode operation will cancel this mode and return the appliance to manual operation. NOTE HEALTH (WiFi) When pressed 8 times in quick succession, this button activates and or resets the WiFi module of the appliance. The appliance will respond with a double beep to confirm WiFI activation or reset. For further details refer to the WiFi Operation Manual, a copy of the manual may be downloaded from the Rinnai  web site: http://www.rinnai.com.au/cooling/ SLEEP MODE 1� Press the "ON/OFF" button to turn on appliance� COOL COOL 2�...
  • Page 12: Delay On Timer

    When the room temperature mode is selected any changes to the set temperature will flash NOTE on the display for 5 seconds, after which the display will revert to displaying the current room temperature. Rinnai Split AC OM...
  • Page 13: Large Temperature Display

    ECO mode operation runs for an 8 hour period, after which normal cooling operations will be resumed, to restart ECO mode after this period repeat step 2 above. NOTE Be aware that ECO mode cooling times may be longer than those for non ECO mode cooling. Rinnai Split AC OM...
  • Page 14: Cleaning Operation

    Return the cover to the closed position� 4� To turn off, repeat steps 1 through 3. POWER INTERRUPTION AUTOMATIC RESTART Should a power outage occur while the appliance is operating, when the power is restored the system will restart  automatically using the same settings as those that were set before the power outage. After power restoration, the automatic restart cycle will take approximately 5 minutes. DO NOT adjust setting during the restart cycle period. NOTE Rinnai Split AC OM...
  • Page 15: Care & Maintenance

    ________________________________________________________________ ________________________________________________________________ CUSTOMER CARE PROGRAM Please ensure you register your product warranty on line at rinnai.com.au. The Rinnai Customer Care Program is designed to help you get the most out of your new system.  Service  and  maintenance  in  accordance  with  the  Service  Maintenance  Schedules  on  page  16  is  essential  in  ensuring  the  prolonged  useful  life  of  your  system,  and  help  ensure  it  operates  at  optimum  efficiency.  We  may ...
  • Page 16: Service Maintenance Schedule - Non Ducted Air Conditioning Systems

    CARE & MAINTENANCE SERVICE MAINTENANCE SCHEDULE - NON DUCTED AIR CONDITIONING SYSTEMS Your Rinnai Air Conditioning System should be maintained annually after the date of installation by a qualified  licensed technician in accordance with the Schedule below. Failure to do so during the product warranty period  may void your warranty. This periodic service and maintenance will prolong the useful life of the unit, and help  keep it running safely and at optimum efficiency. Date of Installation    /           / Installed By: Service Year  Service Date   /           /   /           /   /           /   /           /   /           /   /           / Service Company / Technician Ambient Temperature at CDU (°C) ELECTRICAL Wiring, Electrical connections Fan Motors  Capacitors (if applic) Printed circuit boards MAJOR COMPONENTS Outdoor unit clearances Outdoor unit condensate tray Outdoor unit condensate drain Outdoor unit fixing Indoor unit condensate tray Indoor unit condensate drain / pump...
  • Page 17: General Maintenance

    6� Ensure to re-insert the filter securely after cleaning, observing the same orientation as when removed. Failure to clean the filters regularly can cause condensation to form and drip from the indoor unit when operated in cooling mode during humid conditions. NOTE If you need more filters, please contact Rinnai. Rinnai Split AC OM...
  • Page 18: Save A Service Call

    Remote control doe not operate the Check for interference or obstructions that may be blocking the indoor unit� remote control signals, if interference or obstructions are not responsible then contact Rinnai� The air conditioner stops running� Check power supply or contact Rinnai. If a power failure has occurred. Turn off the air conditioner when a  power failure occurs. When the power is restored, wait 3 minutes, ...
  • Page 19: Warranty

    1�1 “Authorised Service Representative” means an independent service contractor authorised by Rinnai or Rinnai service personnel� 1�2 “Rinnai” means Rinnai Australia Pty� Ltd� ABN 74 005 138 769 and any related company� 1�3 “Certificate(s) of Compliance”  means  certificate(s)  issued  by  licensed  personnel  (including  plumbers, ...
  • Page 20 2�7 Rinnai will reimburse any reasonable costs associated with making a legitimate warranty claim against Rinnai  which are not otherwise specified above. 2�8 The Warranty of the Product requires that, in addition to all other conditions, the Purchaser conducts regular  and/or preventative maintenance as may be specified by the Operating/Installation Instructions or otherwise  directed  by  Rinnai  and  required  by  the  level  of  usage  and  the  usage  environment,  including  the  use  of  correct and uncontaminated refrigerants and lubricants. Refrigeration, plumbing and electrical works must be  undertaken by licensed personnel� 2�9 Where a Product or failed component is replaced under warranty, the time remaining on the original Product  warranty  period  will  continue  to  apply  and  the  replacement  product  or  part  will  be  subject  to  the  original ...
  • Page 21 Warranty, a Proof of Purchase� This document (and any statutory consumer guarantees) represents the only Warranty given by Rinnai in respect of the Product� No other person or organisation is authorised to offer any alternative warranty on behalf of Rinnai.  3�2 If  the  date  of  purchase  cannot  be  established  to  Rinnai’s  satisfaction,  the  date  shall  be  deemed  to  be  2  months after the date of manufacturer or the date of sale by Rinnai, whichever is the latter. 3�3 This warranty applies to Products which are manufactured on or after the date of publication of this warranty ...
  • Page 22 TRAVEL, TRANSPORT & ACCESS COSTS 6�1 The  Purchaser  must  pay  freight  charges,  in-transit  insurance  expenses  and  travelling  costs  for  repairs/ replacements under this Warranty, that are required to be performed 50km from the nearest Rinnai branch or  Authorised Service Representative� 6�2 Subject to clause 6.3, Rinnai will pay freight charges, in-transit insurance expenses and travelling costs for  repairs/replacements that are required to be performed less than 50km from the nearest Rinnai branch or  Authorised Service Representative, subject to the following: a) Rinnai will arrange for such repairs/replacements and make any payment directly to the third party to  provide the freight, in-transit insurance or travel services; or b) if Rinnai considers appropriate, it will authorise the Purchaser in writing to pay for the relevant freight ...
  • Page 23 NOTES Rinnai Split AC OM...
  • Page 24: Contacts

    Braeside, Victoria 3195 AU45204 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced at least every 2 years.