Split type wall mounted air conditioner, system, indoor, outdoor, matching multi system only (36 pages)
Summary of Contents for Rinnai P Series
Page 1
Models REFRIGERANT System Indoor Outdoor HSNRP26 HINRP26M HONRP26 HSNRP35 HINRP35M HONRP35 HSNRP50 HINRP50M HONRP50 HSNRP60 HINRP60M HONRP60 HSNRP70 HINRP70M HONRP70 HSNRP80 HINRP80 HONRP80 HINRP20M Ref Only Matching Multi System Only P Series Split Type Wall Mounted Air Conditioner Operation Manual...
Page 2
OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person� For continued safety of this appliance it must be installed and maintained in accordance with the manufacturer’s instructions� REFRIGERANT Rinnai Split AC OM...
Common Issues ����������������������������������������������������������������������������������������������������������������������������������������������� 13 Installation Record - Installer Details ���������������������������������������������������������������������������������������������������������������� 16 Installation Record - System Details ���������������������������������������������������������������������������������������������������������������� 16 Customer Care Program ���������������������������������������������������������������������������������������������������������������������������������� 16 Service Maintenance Schedule - Non Ducted Air Conditioning Systems ��������������������������������������������������������� 17 Warranty Contacts Rinnai Split AC OM...
For safety and warranty purposes, appliances that may be damaged or incorrect MUST NOT be installed or operated under any circumstances. Installation of damaged or incorrect appliances may contravene local government regulations. Rinnai disclaims any liability or responsibility whatsoever in relation to the installation or operation of damaged or incorrect appliances.
Page 5
Make sure that the area has been made safe by having suitable ventilation and is free from ignition sources before charging or releasing the charge of R32. HSNRP26 HSNRP35 HSNRP50 HSNRP60 HSNRP70 HSNRP80 Model Standard Charge (g) 1260 1260 1400 1400 Minimum Floor Area (m Rinnai Split AC OM...
Page 6
The table below indicates the temperature ranges the air conditioner can be operated within. MODE Cool Mode Heat Mode Dry Mode Room Temperature > 16°C < 30°C > 16°C Outdoor Temperature 0°C ~ 50°C -15°C ~ 24°C 0°C ~ 50°C Rinnai Split AC OM...
” when defrosting “ ” when 8 C heating feature is turned on(some units) ” when Active Clean feature is turned on (For Inverter split type) “ when unit is self-cleaning(For Fixed-speed type) Page 7 Rinnai Split AC OM...
To further optimize the performance of your unit, do the following: Keep doors and windows closed. • Limit energy usage by using TIMER ON and TIMER OFF functions. • Do not block air inlets or outlets. • Regularly inspect and clean air filters. • Rinnai Split AC OM...
Page 9
45 minutes, the unit will turn off automatically and cancel Active Clean function. For multi-split air condtioners, the following functions are not available: Active clean function, Silence feature, Breeze away function, Refrigerant leakage detection function and Eco feature. Rinnai Split AC OM Page 9 ...
Page 10
4. Press the MANUAL CONTROL button again button to activate FORCED COOLING mode. 5. Press the MANUAL CONTROL button a third time to turn the unit off. 6. Close the front panel. Rinnai Split AC OM Page 10 ...
NOTE Failure to clean the filters regularly can cause condensation to form and drip from the indoor unit when operated in cooling mode during humid conditions. If you need more filters, please contact NOTE Rinnai. Page 11 Rinnai...
Page 12
Any unit repairs should be performed • by an authorized dealer or a licensed service provider. Make sure nothing is blocking all air inlets and outlets Rinnai Split AC OM Page 12 ...
This noise is normal and is caused by the refrigerant gas stopping or changing direction. Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by temperature changes during operation can cause squeaking noises. Page 13 Rinnai Split AC OM...
Page 14
Check for leaks, re-seal if necessary and or long-term use top off refrigerant SILENCE function can lower product SILENCE function is activated performance by reducing operating (optional function) frequency. Turn off SILENCE function. Rinnai Split AC OM Page 14 ...
Page 15
• E(x), P(x), F(x) EH(xx), EL(xx), EC(xx) • PH(xx), PL(xx), PC(xx) • NOTE: If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and contact an authorized service center. Rinnai Split AC OM...
Please ensure you register your product warranty on line at rinnai.com.au. The Rinnai Customer Care Program is designed to help you get the most out of your new system. Service and maintenance in accordance with the Service Maintenance Schedules on page 17 is essential in ensuring the prolonged useful life of your system, and help ensure it operates at optimum efficiency.
SERVICE MAINTENANCE SCHEDULE - NON DUCTED AIR CONDITIONING SYSTEMS Your Rinnai Air Conditioning System should be maintained annually after the date of installation by a qualified licensed technician in accordance with the Schedule below. Failure to do so during the product warranty period may void your warranty.
WARRANTY TERMS OF WARRANTY – AUSTRALIA Rinnai Australia Pty. Ltd. ABN 74 005 138 769, 100 Atlantic Drive, Keysborough VIC 3173. NOTICE TO CONSUMERS UNDER AUSTRALIAN CONSUMER LAW Our goods and services come with guarantees that cannot be excluded under the Australian Consumer Law.
Page 19
Normal Business Hours by an Authorised Service Representative. Repair by persons other than an Authorised Service Representatives may void the Warranty. 2�4 Alternatively to clause 2.3 above, Rinnai can at its discretion elect to pay you an amount equivalent to the cost of repairing or replacing the Product.
Page 20
“7 Purchaser’s Responsibilities” on page 21; c) notifies Rinnai within 30 days of a defect occurring or, in the case of a latent defect, becoming apparent, that a claim is being made under this Warranty; and d) provides, in support of the claim made under this Warranty, a Proof of Purchase.
Page 21
Rinnai to enquire about alternative arrangements. If you wish to make a warranty claim in respect of any fixed Product, please contact Rinnai on the details set out below to make arrangements for an Authorised Service Representative to inspect the product.
Help Line. Rinnai recommends that this appliance be serviced every 3 years. With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice. Rinnai Split AC P Series OM R32 Issue 1 - July 2021...