Schaudt LR 1218 Instruction Manual page 12

Solar charge regulator
Hide thumbs Also See for LR 1218:
Table of Contents

Advertisement

Installation instructions for solar charge regulator LR 1218
Connection sequence
Disconnection
6
- -
+
G3
+
- -
Fig. 2
Circuit diagram of connection LR 1218 to starter battery and living area battery
Pos.
Name
F1
Fuse for starter battery charge current (20A)
F2
Fuse for living area battery charge current (20A)
G1
Starter battery
G2
Living area battery
G3
Solar module(s)
LR 1218
Solar charge regulator
*
for display panel (optional)
The connection at the front of the solar charge regulator is established in the
following sequence:
1. Connect the two fuse holders with fuses to the connection cable in ac-
"
cordance with the circuit diagram in Fig. 2. Use the flat push-on con-
tacts (6.3 x 0.8) without sleeve for this (Fig. 1, Pos. 5). After crimping,
attach the insulating sleeves (Fig. 1, Pos. 7). Insert the two fuses.
2. First connect the connection cables for living area battery and starter
"
battery to the solar charge regulator, observing the polarity of the con-
nections. Use the flat push-on contacts (6.3 x 0.8) for this (blue, Fig.
1, Pos. 8).
3. Connect the connection cables for living area battery and starter bat-
"
tery to the batteries.
4. Finally, connect solar modules to the solar charge regulator. Use the
"
flat push-on contacts (6.3 x 0.8) for this (blue, Fig. 1, Pos. 8). The
connection cables for the solar modules should be positioned as clo-
sely as possible to each other to avoid interference of radio reception.
Disconnect in reverse order.
Date: 22.09.2009
LR 1218
*
*
+
--
F1
G1
F2
+
--
G2
822.212 MA / EN

Advertisement

Table of Contents
loading

Table of Contents