30ACi+, 30ACi Deluxe,
35ACi+ and 35ACi Deluxe
Battery Backup System
sides.
6. Install the sump pump in the sump pit, setting
the switch at an appropriate level on the
discharge pipe, and place the sump cover
back on the sump pit so that the pump switch
cord and pump power cord reach the inverter.
7. Plug the switch cord into the back of the
inverter and the pump cord into the switch
cord. See Figure A on this page.
8. Connect the inverter power and turn the MCB
switch to ON position. Your system is now
ready.
9. Powering Up
To charge your battery, make sure the MCB is
in the ON position. The LCD display will come
on and show the condition of the battery. If
the battery is fully charged, the battery display
will have all bars lit and show 100%. If the
battery is charging, the battery display will
cycle the bars from bottom to top and show
the percentage of charge. This shows that the
charger is working properly in AC mode. Any
AC load powered by the inverter should also
work at this point, since a portion of the AC
power is passed through the inverter to power
the load.
The Power button on the front of the inverter is
to be used in the event that the battery needs
to be replaced while the unit is in DC mode,
See Page 3, Replacing Battery. If setting up
the inverter when AC power is available, the
Power button is automatically on. If the button
is held in for 3 - 5 seconds while in AC mode,
the display will go blank and the inverter will
be off. The inverter can be turned back on by
holding in the Power button again for 3 - 5
seconds or unplugging the inverter from the
wall outlet for 10 seconds and plugging it back
in.
Note: The range of the switch is the distance
between the On and Off levels. The Off level is at the
bracket mounting screw of the switch. From this point,
measure up to find the On level, see Figure B on this
page.
The Ion+® switch does not operate like a standard
pressure switch. There are no contacts to wear out,
OPERATION MANUAL
Dated: 02/10/2015
Document Name: 30-35ACi+&Deluxe_OM
so when pressure is applied, there will not be a click.
10. Testing
While the inverter is on AC power, fill the basin
up with a bucket or garden hose to verify that
the pump turns on at the correct level. Once
the pump turns on, let it pump the basin out
until it shuts off. Repeat three times.
Unplug the power cord from the wall outlet. The
inverter will beep with the battery bars cycling
from top to bottom. The battery percentage
will slowly start to drop. The inverter is now
in DC mode, taking the battery power and
using it to power the load uninterrupted. Fill
the basin again, as described above, to verify
the pump's operation in DC mode. Make sure
you plug the inverter back into the wall outlet.
The above steps will complete a function test of
the inverter. If all areas pass, the inverter is ready
for use. If any areas fail, see the troubleshooting
table.
Ion+
Piggyback
Pump
Plug
Figure B
8" Range
Alarm
6" Range
On
Factory-set ranges for Ion+
Register your product at www.sumpro.com
Page 5 of 12