ION 30ACi+ Operation Manual page 10

Battery backup system
Table of Contents

Advertisement

30ACi+, 30ACi Deluxe,
35ACi+ and 35ACi Deluxe
Battery Backup System
13. Fuse Blows or Circuit Breaker Trips
a. Pump impeller may be partially clogged
with tar or paint, causing motor to run slow
and overload. Remove pump and clean.
b. Motor stator may be defective.
c. Fuse size or circuit breaker may be too
small. Must be 15 amp.
d. Impeller or volute opening may be fully or
partially clogged. Remove pump and clean.
14. Motor Runs for a Short Time Then Stops
a. Inlet holes in pump base may be clogged.
Remove pump and clean the openings.
b. Pump impeller may partially clogged with
tar or paint, causing motor to run slow and
overload. Remove pump and clean.
c. Motor stator may be defective.
15. Pump Does Not Turn On
a. Test the pump without the Ion+ switch/
alarm.
i. Plug the pump directly into a wall outlet,
without plugging it into the Ion+ switch/
alarm plug.
ii. If pump still does not run, the pump
may be defective.
iii. If the pump does run, continue to the
next step.
b. Test the Ion+ switch/alarm with the pump.
i. Plug the pump into the Ion+ switch/
alarm and plug the Ion+ switch/alarm
plug into the wall outlet.
ii. Push up on the sensing plate through
the center hole on the underside of the
switch. Note that, being an electronic
switch, you will not hear a clicking
sound.
iii. If the pump does not turn on, the Ion+
switch/alarm may have to be replaced.
iv. If the pump does turn on, continue to
Register your product at www.sumpro.com
OPERATION MANUAL
Dated: 02/10/2015
Document Name: 30-35ACi+&Deluxe_OM
the next step.
c. Verify the range of the Ion+ switch/alarm.
Your system should have been supplied
with a 6" range switch.
i. See Page 5, Figure A to verify that the
On level is appropriate for your basin.
If the On level is too high, contact the
installer.
Page 10 of 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30aci deluxe35aci deluxe35aci+

Table of Contents