Specifications; Electric Braising Pan; Gas Braising Pan; Tools - Vulcan-Hart VGCTS16 Service Manual

Round counter top tilting braising pans (16 gallon) gas and electric
Table of Contents

Advertisement

Electric Braising Pan

1 PHASE
TOTAL
MODEL
208V
KW
VECTS16
7.5
36

Gas Braising Pan

INPUT
BTU/HR
MODEL
NAT.
PROP.
VGCTS16
30,000 30,000

TOOLS

Standard

Standard set of hand tools.

VOM with an AC current tester (meter sensitivity should be at least 20,000 ohms per volt can be used).

Gas leak checking equipment.

Manometer

Temperature meter (thermocouple type)
ROUND TILTING BRAISING PANS - GENERAL

SPECIFICATIONS

AMPERAGE
3 PHASE
240V
208V
240V
480V
31.3
20.8
18.1
9.0
MANIFOLD
PRESSURE
(INCHES W.C.)
NATURAL
NAT.
PROP.
RECOMMEND
3.5
10.0
7.0
Page 4 of 24
LINE PRESSURE
(INCHES W.C.)
PROPANE
MIN
RECOMMEND
MIN
5.0
11.0
11.0
AMPS
(MAX)
LOAD
(WATTS)
120V
MAX
60HZ
1.5
14.0
180

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml-114827Vects16Ml-114825

Table of Contents