Omron E2E series Network Connection Manual page 21

Io-link connection guide (ethercat(r) host communications); proximity sensor (io-link); io-link master unit; ethercat coupler unit
Table of Contents

Advertisement

7.3.2.
Setting up the EtherCAT Network Configuration
Set up the EtherCAT network configuration.
1
Double-click EtherCAT under
Configurations and Setup in
the Multiview Explorer.
2
The EtherCAT Tab Page is
displayed in the Edit Pane.
3
Right-click Master on the
EtherCAT Tab Page in the Edit
Pane and select Compare and
Merge with Actual Network
Configuration.
A screen is displayed stating
"Get information is being
executed".
4
The Compare and Merge with
Actual Network Configuration
Dialog Box is displayed.
Node address 1 and
NX-ECC202 Rev:1.2 are added
to the Actual network
configuration after the
comparison.
Click Apply actual network
configuration.
7.IO-Link Connection Procedure
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx series

Table of Contents