Operational Characteristics 1800 Lb System - Scotsman Prodigy Plus E Series Installation And User Manual

Eclipse cuber with condensing unit
Hide thumbs Also See for Prodigy Plus E Series:
Table of Contents

Advertisement

EH330, EH430 E and ECC Condensing Unit
Remote Low Side Cuber User Manual

Operational Characteristics 1800 lb system

Cycle Times @ Condenser Temp/Cabinet Temp/Water Temp in degrees F.
Freeze
Harvest
System Pressures @ Condenser Temp/Cabinet Temp/Water Temp in degrees F
Suction at head, end of Freeze
Suction at head, Harvest - Peak
Discharge at Condensing Unit:
Freeze - 5 minutes in
Headmaster maintains a minimum discharge pressure during freeze of 217 PSIG + 25, -15 PSIG.
CPR Valve Setting: 55 - 60 PSIG.
Note: CPR allows a maximum low side pressure at the compressor. Maximum only occurs during harvest.
Refrigerant Charge
1800 - 232 oz
Compressor Amps, 1800
Three Phase - 10 to 14
Batch Weight: 13 to 14 lb
Discharge Pressure Cut Out Switch
Cuts Out at: 450 PSIG Resets at: 350 PSIG
70/70/50
10 to 14 minutes
1 to 1.5 minutes
70/70/50
25 to 35 PSIG
80 to 100 PSIG
260 to 280 PSIG
August 2017
Page 22
90/90/70
12 to 16 minutes
1 to 1.5 minutes
90/90/70
25 to 35 PSIG
90 to 110 PSIG
260 to 280 PSIG
120/110/100
17 to 19 minutes
.5 to 1 minute
120/110/100
25 to 35 PSIG
140 t0 160 PSIG
330 to 350 PSIG