Operational Characteristics; December - Scotsman CSWE1 Product Manual

Scotsman cswe1 ice machine: user guide
Table of Contents

Advertisement

CSWE1

Operational Characteristics

Water Solenoid Valve
.25 GPM flow rate
Evaporator
Stainless steel
Refrigerant Charge
6.75 oz. of R-134a
Running amps
3.5
Cutter grid
8.5 volts
1.9 amps
Evaporator thermostat
o
Cut in: 38
F.
o
Cut out: 10 to -4
F.
Bin thermostat
o
Cut in: 41
F.
o
Cut out: 35
F.
System Pressures
Temperature
o
o
Air 70
F., water 60
F.
o
o
Air 90
F., water 60
F.
o
o
Air 100
F., water 60
F.
o
o
Air 70
F., water 80
F.
o
o
Air 90
F., water 80
F.
o
o
Air 100
F., water 80
F.
Suction Pressure at the
end of the freeze cycle
(PSIG)
1 - 4
2 - 5
2 - 8
1 - 4
2 - 5
2 - 6

December 1995

Discharge pressure at
the end of the freeze
cycle (PSIG)
65 - 80
85 - 100
85 - 105
65 - 80
85 - 100
85 - 105
Page 14
Cycle time in minutes
18 - 22
21 - 27
28 - 35
20 - 25
23 - 30
30 - 38