11. Exhaust Gas System
11.3.7.4
Conventional exhaust gas silencer (5R02)
Yard/designer should take into account that unfavourable layout of the exhaust system (length
of straight parts in the exhaust system) might cause amplification of the exhaust noise between
engine outlet and the silencer. Hence the attenuation of the silencer does not give any absolute
guarantee for the noise level after the silencer.
When included in the scope of supply, the standard silencer is of the absorption type, equipped
with a spark arrester. It is also provided with a soot collector and a condense drain, but it
comes without mounting brackets and insulation. The silencer can be mounted either
horizontally or vertically.
The noise attenuation of the standard silencer is either 25 or 35 dB(A). This attenuation is valid
up to a flow velocity of max. 40 m/s.
Fig 11-8
Table 11-1
NS
900
1000
1100
1300
1400
1500
Flanges: DIN 2501
11-10
Exhaust gas silencer
Typical dimensions of exhaust gas silencers
A [mm]
B [mm]
C [mm]
860
1190
2240
870
1280
2340
900
1340
2600
950
1440
2650
950
1490
2680
1000
1540
2680
Attenuation: 25 dB(A)
ØD
[mm]
L [mm]
Weight [kg]
1800
5360
2295
1900
5880
2900
2100
6200
3590
2300
7500
4980
2400
8165
5800
2500
8165
6180
Wärtsilä 46F Product Guide - a19 - 1 December 2017
Wärtsilä 46F Product Guide
Attenuation: 35 dB(A)
L [mm]
Weight [kg]
6870
2900
7620
3730
8200
4780
9500
6540
10165
7120
10165
7650