ECO-ADV-WS22
M. Blower Operating Instructions
NOTE: If your wood appliance is equipped with an
optional blower, you should follow these
guidelines:
Burn Rate
Air Control
Figure 16.1
1. Initial (cold) startup:
raising the Burn Rate Air Control all the way up until
it stops and push the Start-up Air Control back until it
stops.
The blower tends to cool the appliance. Leave
the blower off until the burn is well established, i.e., 30
minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is
fully pushed in. Blower may remain on.
3. Medium High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4. Medium Low Burn Setting*: Burn Rate Air Control
is closed then opened to 1/4 inch to 1/2 inch. Leave
the blower off until the burn is well established, i.e., 30
minutes.
5. Low Burn Setting*: Burn Rate Air Control is closed.
Leave the blower off until the burn is well established,
i.e., 30 minutes.
When reloading the appliance, raise the Burn Rate
Air Control all the wall to the High setting for 5 to 15
minutes before setting to the desired burn rate.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward
to activate the Automatic Combustion Control
(ACC).
NOTE: For maximum efficiency and lowest emissions,
when operating the blower in either the automatic
or manual setting for the low and medium low
burn settings leave the blower off until the burn is
well established, i.e., 30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards "OFF" as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible
16
Handle Up = Open
Handle Down = Closed
Open both controls fully by
7057-128K • October 24, 2018
Blower
Figure 16.2 - Snap Disc Location
7. Snap Disc Location: If you find the blower coming
on and off at undesirable temperatures, relocate the
snap disc to another location in the designated zone
on the back of the appliance (Figure 16.2). There is a
manual over-ride switch to deactivate the snap disc, if
necessary. See page 39 for location of over-ride switch.
N. Opacity (Smoke)
This is the measure of how cleanly your appliance is
burning. Opacity is measured in percent; 100% opacity is
when an object is totally obscured by the smoke column
from a chimney, and 0% opacity means that no smoke
column can be seen. As you become familiar with your
appliance, you should periodically check the opacity. This
will allow you to know how to burn as nearly smoke-free as
possible (goal of 0% opacity).
CAUTION
When burning your first fire, you will experience smoke
and odor from the appliance resulting from the curing
of paint and burning off of any oils remaining from
manufacturing.
OPEN WINDOWS DURING INITIAL BURN TO
DISSIPATE SMOKE AND ODORS!
Odors may be irritating to sensitive individuals.
Smoke detectors may activate.
Snap Disc
www.heatilatorecochoice.com