7.2 Standards and regulations
The router complies with the following standards and regulations.
Standards and regulations
Radio
EMC
Safety
National
7.3 Type tests and environmental conditions
Phenomena
Test
ESD
EN 61000-4-2
RF field AM
EN 61000-4-3
modulated
Fast transient
EN 61000-4-4
Surge
EN 61000-4-5
RF conducted
EN 61000-4-6
Radiated emission
EN 55022
Conducted
EN 55022
emission
Power frequency
EN 61000-4-8
magnetic field
Dry heat
EN 60068-2-2
Cold
EN 60068-2-1
Dump heat
EN 60068-2-78
Table 23: Type tests and environmental conditions
* The temperatures given are for the basic version of the router. These can vary for other versions.
AS/CA S042-2015
IEC 61000-6-2:2005, IEC 61000-6-3:2006
IEC 60950-1:2005 (second edition) + A1:2009 + A2:2013,
AS/NZS 60950.1:2015
RCM
Table 22: Standards and regulations
Description
Enclosure contact
Enclosure air
Enclosure
Signal ports
Power ports
Ethernet ports
Ethernet ports
Power ports
I/O ports
All ports
Enclosure
DC power ports
Ethernet ports
Enclosure
+75 C *, 40 % rel. humidity
-40 C *
95 % rel. humidity (+40 C)
37
SmartFlex SR308
Test levels
6 kV (crit. A)
8 kV (crit. A)
20 V/m (crit. A)
(80 – 2700 MHz)
3 V/m (crit. A)
(2700 – 6000 MHz)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. A)
2 kV (crit. B), shielded cab.
0,5 kV (crit. B)
1 kV, L to L (crit. A)
2 kV, L to GND (crit. A)
10 V/m (crit. A)
(0,15 – 80 MHz)
Class B
Class B
Class B
160 A/m (crit. A)