Rane CP 64 Operator's Manual page 11

Commercial processor
Table of Contents

Advertisement

RECOMMENDED CALIBRATION PROCEDURE
The CP 64 is a very versatile instrument. While this allows it to conform to the requirements of a large number of system
applications, it also results in complexity. For this reason, it is very important to use an organized approach to system calibra-
tion. Once the internal switches are set and the system is connected, take the time for proper calibration. The following is an
ordered list of system adjustments that should make calibration easy and result in optimum performance. Most important:
• Program Priority Assign is set to Off
• Ducker is Off
• Zone Limit Threshold is set to +20 dBu
• Page Zone Levels are set to minimum
• Remote Control is not selected
• Page Zone Assign is set to Both
The following procedure assumes that microphones are used for Page sources. The procedure (except for the exact
wording) is the same for other Page sources.
Make sure the POWER is off!
Control Presets:
Page settings (repeat for second page input):
• Input Pad
• Input gain trim
• Detector Threshold
• Paging assign
• Paging Level, Zone 1
• Paging Level, Zone 2
• Phantom Power
• Pre/Post summing
• Page Priority
Program Input settings:
• Input Level controls
• Program Priority Input Threshold
• Program Priority Input Release Time
• Program Priority Assign
Zone Settings (repeat for second zone):
• Zone Level
• Program Select
• Ducker
• Ducker Depth
• RMT (Remote)
• EQ
• Stereo/Mono switch
• Expand Source
• Limiter Threshold
System Connections:
• Connect Page Microphones or Line Level paging source
• Connect Program Sources
• Connect Outputs to Amps
• Connect Remote Controls
You are now ready to calibrate the CP 64...
Mic/Line as required
Center (12:00)
Min (ccw, Active)
Both
Min
Min
As required. Default Off
As required. Default Pre-VCA
As required. Default Page 1
Min
Set to −50 at factory (internal adjust −∞ to −35 dBu)
Set to 12 sec. at factory (internal adjust 2 to 20 sec.)
Off
Max
L1 (if your input is on L1).
OFF
Center (about 15 dB)
Out (front panel)
Flat (center detent position)
As required (internal - zone 1 only, default:stereo)
As required (Zone/Program/Page)
+20 dBu
(internal)
(internal)
(internal)
Manual-11

Advertisement

Table of Contents
loading