Champion 73001i-DF (EU) Owner's Manual & Operating Instructions

Champion 73001i-DF (EU) Owner's Manual & Operating Instructions

Electric start dual fuel inverter generator

Advertisement

Electric Start
DUAL FUEL INVERTER GENERATOR
U.S. Patent No. D710,802
This manual covers the following models:
73001I-DF (EU)
SAVE THESE INSTRUCTIONS
Important safety instructions
are included in this manual.
OWNER'S MANUAL & OPERATING INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 73001i-DF (EU) and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Champion 73001i-DF (EU)

  • Page 1 OWNER’S MANUAL & OPERATING INSTRUCTIONS Electric Start DUAL FUEL INVERTER GENERATOR U.S. Patent No. D710,802 This manual covers the following models: 73001I-DF (EU) SAVE THESE INSTRUCTIONS Important safety instructions are included in this manual.
  • Page 2: Manual Conventions

    WARNING indicates a potentially hazardous help. Please contact your local dealer. situation which, if not avoided, could result in death or serious injury. Champion Power Equipment Support CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor Model Number or moderate injury.
  • Page 3: Safety Rules

    SAFETy RULES SAFETy RULES WARNING DANGER WARNING WARNING Generator produces powerful voltage. Read this manual thoroughly before operating your Medical and Life Support Uses. Rapid retraction of the starter cord will pull hand and generator. Failure to follow instructions could result arm towards the engine faster than you can let go.
  • Page 4 Artwork Notes Revision Changes This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for 3mm corner radius; 2mm safe margin; white to be B: Updated size match DF generator outside parties without the explicit consent of Champion Power Equipment.
  • Page 5 ASSEMBLy ASSEMBLy Add Engine Oil Add Engine Oil Cont’d. Your generator requires some assembly. This unit ships Connecting the Battery Cont’d. from our factory without oil. It must be properly serviced CAUTION Degrees Celsiusº (Outside) NOTE with fuel and oil before operation. If the battery cables are not visible once the battery DO NOT attempt to crank or start the engine before Remove the Generator from the Shipping Carton...
  • Page 6 ASSEMBLy ASSEMBLy Add Fuel (Petrol) Add Fuel Cont’d. Connecting the Propane (LPG) Cylinder Connecting LPG Cylinder Cont’d. Make sure the fuel selector switch on the inverter is Use clean, fresh, regular unleaded fuel with a CAUTION NOTE in the 12 o’clock (vertical) position. (A) minimum octane rating of 85 and an ethanol content of less than 10% by volume.
  • Page 7: Operation

    OPERATION OPERATION Generator Location Grounding Starting the Inverter Petrol NEVER operate the generator inside any building, The generator system ground connects the frame to the CAUTION NOTE including garages, basements, crawlspaces and sheds, ground terminals on the power panel. The system ground is enclosure or compartment, including the generator If the ignition switch is held down in the “Start”...
  • Page 8: Economy Control Switch

    14. If engine fails to start in 1-pull with choke in the heated by flowing over the engine. The container “RUN” position, then pull choke out and repeat the Two (2) Champion model 73001I-DF (EU) generators WARNING should not be placed in the path of the muffler PULL-TO-PRIME step.
  • Page 9 OPERATION OPERATION Do Not Overload Generator Stopping the Engine Operation at High Altitude Overload Operation Turn off and unplug all electrical loads. Never start The density of air at high altitude is lower than at sea The overload indicator light will turn on when the rated Capacity or stop the generator with electrical devices plugged load is exceeded.
  • Page 10: Maintenance And Storage

    GFCI trips automatically to stop the must be bonded to ground or to the generator frame. Your management facility. Champion generator comes with the neutral wire already Never operate a damaged or defective generator. flow of electricity and prevent serious injury. The green bonded to the frame.
  • Page 11: Generator Battery

    *To be performed by knowledgeable, experienced owners or A Float Charger will maintain the battery condition Remove the spark arrester screen. Champion Power Equipment certified dealers. over long storage periods. Carefully remove the carbon deposits from the spark arrester screen with a wire brush.
  • Page 12: Troubleshooting

    MAINTENANCE AND STORAGE TROUBLESHOOTING Storage Problem Cause Solution Generator will not start No fuel Add fuel The generator should be started at least once every Faulty spark plug Replace spark plug 14 days and allowed to run for at least 20 minutes. Unit loaded during start up Remove load from unit For longer term storage, please follow these guidelines.
  • Page 13: Specifications

    Noise Level 59.0 dBA Inverter Parallel Capability DC Operation Voltmeter Automatic Voltage Regulation Battery Start Type Recoil, Electric Engine Brand Champion Engine Size 192cc Engine Type 4-stroke Engine Speed Variable Fuel Type Gasoline, Propane (LPG) Fuel Gauge Gasoline Capacity Gasoline Tank Material...
  • Page 14 TECHNICAL DIAGRAMS TECHNICAL DIAGRAMS 73001I-DF (EU) PARTS DIAGRAM 73001I-DF (EU) PARTS LIST...
  • Page 15 TECHNICAL DIAGRAMS TECHNICAL DIAGRAMS 73001I-DF (EU) PARTS DIAGRAM 73001I-DF (EU) PARTS LIST . n i , l e , t l l f f , t l , y l l f f , t f , t l , t l 1.9074.4.0512.1 Screw/Washer Assembly, M5 x 12, Black 5.1320.023...
  • Page 16 Page intentionally left blank. Page intentionally left blank.