omnidirectional air vent: 1000 mm
air vent directed away from the sensor: 500 mm
The sensor must be installed to the place defined
in these instructions. If the minimum distance is not
fulfilled, ventilation must be changed.

3.4.2. Electric Heater Insulation Resistance

When performing the final inspection of the electrical
installations, a "leakage" may be detected when
measuring the heater's insulation resistance. The
reason for this is that the insulating material of the
heating elements has absorbed moisture from the
air (storage/transport). After operating the heater
for a few times, the moisture will be removed from
the heating elements.
Do not connect the power feed for the heater
through the RCD (residual current device)!
Group I
Gruppe I
Figure 5.
The heater's electrical connections
Abbildung 5
Elektroanschlüsse des Saunaofens
Group II
Gruppe II
DE
Luftzufuhr:
Mehrrichtungs-Luftzufuhr: 1000 mm
Luftzufuhr weist vom Fühler weg: 500 mm
Der Fühler muss an der Stelle angebracht werden,
die in diesen Anweisungen angegeben wird. Wenn
der Mindestabstand nicht erfüllt ist, muss die Luft-
zufuhr geändert werden.

3.4.2. Isolationswiderstand des Elektrosaunaofens

Bei der Endkontrolle der Elektroinstallationen kann
bei der Messung des Isolationswiderstandes ein
"Leck" auftreten, was darauf zurückzuführen ist,
daß Feuchtigkeit aus der Luft in das Isolationsmateri-
al der Heizwiderstände eingetreten ist (bei Lagerung
und Transport). Die Feuchtigkeit entweicht aus den
Widerständen nach zwei Erwärmungen.
Schalten Sie den Netzstrom des Elektrosauna-
ofens nicht über den Fehlerstromschalter ein!