Siemens RDF110 Manual page 8

Rdf11 series room temperature controllers with lcd or 2-pipe fan coil units for compressors in dx type equipment
Table of Contents

Advertisement

Control parameters of the RDF110 and RDF110.2
Para-
Meaning
meter
Setpoint of heating in
P01
Setpoint of cooling in
P02
P03
Setpoint of heating in
P04
Setpoint of cooling in
P05
Minimum setpoint limitation in Normal operation
P06
Maximum setpoint limitation in Normal operation
P07
Sensor calibration
P08
Switching differential heating mode SDH
P09
Switching differential cooling mode SDC
P10
Switching differential fan speed 2 in heating mode SDH2
P11
Switching differential fan speed 2 in cooling mode SDC2
P12
Switching differential fan speed 3 in heating mode SDH3
P13
Switching differential fan speed 3 in cooling mode SDC3
P14
Dwelling time of auto fan speeds
P15
Minimum output on time (Y11)
P16
Minimum output off time (Y11)
P17
Selection of °C or °F
P18
Display of temperature or setpoint
P19
Operating action of remote changeover input
P20
Economy (Energy saving)
Fan control in
P21
Fan control in Normal operation
P22
Heating / cooling mode
P23
Heating / cooling changeover switching point cooling
P24
Heating / cooling changeover switching point heating
P25
Infrared receiver (only with RDF.../IR)
P98
Active temperature sensor
Value of current heating / cooling changeover temperature
P99
reading and indication of current mode
1) Not available with RDF110.2
Type summary
8/14
Siemens
Building Technologies
Economy (Energy saving)
Economy (Energy saving)
Protection (Standby)
Protection (Standby)
mode
Type
Features
RDF110
With input for automatic heating / cooling changeover or return air
temperature sensor
With input for operating mode changeover
RDF110.2
With manual heating / cooling changeover
Without input for sensor
Without input for operating mode changeover
*)
RDF110/IR
Same as RDF110 plus infrared remote control
*)
RDF110.2/IR
Same as RDF110.2 plus infrared remote control
*) Type is not orderable any more
Room Temperature Controllers
Setting range
mode
OFF, 5 °C...Wcool
(Wheat
)
Eco
mode
OFF, Wheat
(Wcool
)
Eco
OFF, 5 °C...Wcool
(Wheat
)
Stb
OFF, Wheat
(Wcool
)
Stb
(Wmin
)
5 °C...Wmax
Comf
(Wmax
)
Wmin
Comf
-3...+3 K
0.5...+4K
0.5...+4K
0.5...+4K
0.5...+4K
0.5...+4K
0.5...+4K
1...5 minutes
1...10 minutes
1...10 minutes
°C or °F
OFF: Setpoint
ON: Room (or return air)
temperature
0: Normally open (N.O)
1: Normally closed (N.C.)
OFF in dead zone
ON in dead zone
OFF in dead zone
ON in dead zone
0: Heating only
1: Cooling only
2: Automatic H/C
changeover
10...25 °C
27...40 °C
0: Disabled
1: Enabled
0: Internal sensor
1: External sensor
100 = input open 
0...49 °C = cur. temp. value
00 = input bridged 
mode
OFF= not commissioned as
automatic H/C changeover
Factory
setting
16 °C
Eco
28 °C
...40 °C
Eco
OFF
Stb
...40 °C
OFF
Stb
5 °C
Comf
...40 °C
35 °C
Comf
0 K
2 K
1 K
1 K
1 K
1 K
1 K
2 min
1 min
1 min
°C
ON
0
OFF
OFF
1: Cooling
16 °C
28 °C
1
Diagnostic
value
mode
Diagnostic
value
1)
1)
1)
1)
1)
only
1)
1)
1)
1)
N3057en
2014-10-28