• For opening or closing two valves and for switching a three-speed fan. Suitable for four-pipe fan coil unit systems with: • automatic heating/cooling changeover. • continuous heating or cooling mode. Product Number RDF30U Siemens Industry, Inc.
Technical Instructions RDF30U Room Temperature Controller with LCD Document Number 155-335 for Four-Pipe Fan Coil Units September 27, 2007 Accessories ARG70 Adapter plate for 4-inch × 4-inch or 2-inch × 4-inch conduit boxes 141-570 Lockable thermostat guard QAH11.1 Changeover/remote temperature sensor...
Figure 1. Water-based Fan Coil Heating and Cooling Mode. Return Air Temperature The RDF30U provides control based on the measured room temperature or the fan coil (Optional) unit’s return air temperature. It detects if a QAH11.1 cable temperature sensor is connected to input 9-8 and then operates automatically according to that temperature.
Page 4
Technical Instructions RDF30U Room Temperature Controller with LCD Document Number 155-335 for Four-Pipe Fan Coil Units September 27, 2007 Avoiding damage due to To avoid damage due to moisture in very warm and humid climates resulting from lack moisture (continuous...
Page 5
RDF30U Room Temperature Controller with LCD Technical Instructions For Four-Pipe Fan Coil Units Document Number 155-335 September 27, 2007 Table 1. Control Parameters. Para- Description Setting Range Factory meter Setting Heating setpoint in Economy mode OFF, 61F (operating mode changeover contact activated ) 41F to 68F (5C to 20C) (in increments...
Technical Instructions RDF30U Room Temperature Controller with LCD Document Number 155-335 for Four-Pipe Fan Coil Units September 27, 2007 Ordering The QAH11.1 temperature sensor can be used as a return air temperature sensor. The changeover sensor and the valves must be ordered separately.
Page 7
RDF30U Room Temperature Controller with LCD Technical Instructions For Four-Pipe Fan Coil Units Document Number 155-335 September 27, 2007 Table 3. DIP Switches. DIP Switch Description Position ON (Factory Setting) Position OFF Fan control Fan control is temperature- Fan control is temperature-...
The cables used must meet the insulation requirements for live voltage. Calibrating the Sensor If the room temperature displayed by the controller is inconsistent with the room temperature being measured, the temperature sensor of the RDF30U can be recalibrated. To recalibrate, change Parameter P09. Operating voltage 24 Vac, +20/-25%...
RDF30U Room Temperature Controller with LCD Technical Instructions For Four-Pipe Fan Coil Units Document Number 155-335 September 27, 2007 Operation Specifications, Temperature 32°F to 122°F (0°C to 50°C) Continued Humidity <95% rh Environmental Conditions Transport and storage Temperature -13°F to 158°F (-25°C to 70°C) Humidity <95% rh...
Page 10
Inches (Millimeters) Figure 7. Base Plate. Figure 6. RDF30U Controller. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners.