Specifications - GE ETS series Technical Service Manual

Louisville built top mount no frost 18-19 cu. ft. energy refrigerators
Table of Contents

Advertisement

DISCONNECT POWER CORD BEFORE SERVICING
IMPORTANT - RECONNECT ALL GROUNDING DEVICES
All parts of this appliance capable of conducting
electrical current are grounded. If grounding wires,
screws, straps, clips, nuts or washers used to
complete a path to ground are removed for service,
they must be returned to their original position and
properly fastened.
ELECTRICAL SPECIFICATIONS
Temperature Control (Position 5) .............................. 24.5-12.5°F
Defrost Control ..................................................... 8 hrs. @ 30 min.
Defrost Thermostat ............................................................ 58-28°F
Electrical Rating: 115V AC 60Hz.
100V AC 50 Hz. .............................................................. 6.5 Amp.
Maximum Current Leakage ............................................. 0.75 mA.
Maximum Ground Path Resistance ........................... 0.14 Ohms
Energy Consumption
18' .............................................................................. 40 KWH/mo
19' .............................................................................. 41 KWH/mo
NO LOAD PERFORMANCE
Control Position, Fresh Food 5, Freezer 5
and Ambient Temperature of: ............................. 70°F
Fresh Food, °F ....................................................... 34-40
Frozen Food, °F ..................................................... (-3) -4
Run Time, % .......................................................... 20-30
REFRIGERATION SYSTEM
Refrigerant Charge (R134a) ........................................ 4.0 ounces
Compressor ................................................................... 679 BTU/hr
Minimum Compressor Capacity ................................... 19 inches
Minimum Equalized Pressure
@70°F ............................................................................... 52 PSIG
@90°F ............................................................................... 66 PSIG
REPLACEMENT PARTS
Condenser Fan Motor ............................................... WR60X10044
Evaporator Fan Motor .............................................. WR60X10057
Defrost Heater ........................................................... WR51X10031
Relay ............................................................................ WR07X10031
Overload ........................................................................ WR08X0167
Temperature Control ................................................. WR09X10044
Defrost Control ................................................................ WR9X503
Defrost Thermostat ................................................... WR50X10025
Capacitor .................................................................... WR062X0087

Specifications

IMPORTANT SAFETY NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical,
electronic and mechanical experience. Any attempt
to repair a major appliance may result in personal
injury and property damage. The manufacturer or
seller cannot be responsible for the interpretation
of this information, nor can it assume any liability
in connection with its use.
INSTALLATION
Clearance must be provided for air circulation
AT TOP .....................................................................................1-inch
AT SIDES ............................................................................. 1/8-inch
AT REAR ..................................................................................1-inch
AIR FLOW
FAN
EVAPORATOR
90°F
35-39
(-3) -3
41-53
COLD AIR
– 2 –
SEALED SYSTEM
CONDENSER
LOOP
DAMPER
103-02A
MIXED AIR
WARMER AIR
ND103-02B
T
PROCESS
TUBE
DRYER