Specifications - GE GYE18JBL Technical Service Manual

Bottom-freezer refrigerators
Table of Contents

Advertisement

Electrical Shock Hazard
WARNING
Death or serious injury can result from failure
to follow these instructions.
• Service by a qualified service technician
only.
• Disconnect power before servicing this
product.
• Reconnect all grounding devices after
service.
• Replace all parts and panels before
operating.
ELECTRICAL SPECIFICATIONS
Max Defrost Control
w/No Door Openings
Evap Defrost Thermostat
Defrost Heater
Fill Tube Heater
Mullion Heater
Recess Heater
Duct Door Heater
Duct Door Motor
Damper Motor
Isolation Valve
Icemaker Valve
Dispenser Valve
Compressor Windings
Ice Blower Fan
Evaporator Fan
Condenser Fan
Auger Motor
Icemaker

Specifications

96 hrs @ 40 min
95 - 65°F
120 VAC / 33
Ω
13 VDC / 136
Ω
13 VDC / 24
Ω
13 VDC / 100
Ω
120 VAC / 1100
Ω
13 VDC / 15
Ω
415
Ω
120 VAC / 320
Ω
120 VAC / 320
Ω
120 VAC / 120
Ω
120 VAC / 4
6
Ω &
Ω
6-13 VDC
8-11 VDC
9-10 VDC
120 VAC
120 VAC
– 11 –
NO LOAD PERFORMANCE
CONTROL POSITION 0 / 37°F and
AMBIENT TEMPERATURE OF
Fresh Food, °F
Frozen Food, °F
Percent Running Time
REFRIGERATION SYSTEM
Minimum Equalized Pressure
@ 70°F
@ 90°F
R134a Refrig. Chg.
18 cu. ft. models:
24 cu. ft. models:
26 cu. ft. models:
REFRIGERATION DIAGNOSIS
To access the low pressure side of the system,
install a WJ56X61 valve only on the process
tube extending from the compressor case.
65°F
90°F
38 - 40
36 - 38
0 - 1
0 - 2
25 - 50
50 - 80
40/45 PSIG
48/60 PSIG
4.00 ounces