For Your Safety; Electrical Information; Working Temperature Range - Toshiba RAC-H07CR Owner's Manual

Table of Contents

Advertisement

Safety Precautions
EN
Immediately cut off the main power supply to
stop the air conditioner if there is a possibility
of lightning strike
Disconnect the power cord plug from socket if
left unused for a long period
Hold the head of the plug when pulling the
power cord plug out
Air dry at shady place after panel or filter
being washed
Confirm the circuit breaker is well installed
Can't be used for store of food, animals and
plants, precision instrument, artistic products
or used on vessels or vehicle
Be sure not to operate long time when doors
and windows are open
Be sure not to put any other electric appliances
or furniture under the air conditioner
Be sure not to put any other things on top of
the air conditioner
Batteries for remote controller
05
CAUTION
Or else it may cause damage of air conditioner.
Or else it may cause abnormal heating or fire.
Or else it may cause break of core
wire and result in wire or abnormal heating.
Or else it may cause electric shock.
dealer or Toshiba air conditioning service hotline.
It may cause poor performance or damage.
It may cause water leakage or insulation aging and result in fire
and electric shock.
It may cause dirty or damage or malfunction.
It may cause malfunction or fall of the air conditioner.
batteries into fire, as it could cause battery leakage and may
result in physical injury. Rinsing immediately if touch the liquid
leaked from battery by accident.
advice if battery has been swallowed.
Warnings on refrigerant leakage
Check of concentration limit
The room in which the air conditioner is to be installed requires a design that in the event of refrigerant gas
leaking out, its concentration will not exceed a set limit.
The refrigerant R410A which is used in the air conditioner is safe, without the toxicity or combustibility of
more than air, it poses the risk of suffocation if its concentration should rise excessively.
If a conditioner system is to be installed in a small room, select a suitable model and installation procedure so
that if the refrigerant accidentally leaks out, it's concentration does not reach the limit (and in the event of an
emergency, measures can be made before injury can occur). In a room where the concentration may exceed the
limit, create an opening with adjacent room or install mechanical ventilation combined with a gas leak detection device.
The concentration is as given below.
Total amount of refrigerant (kg)
Min. volume of the unit installed room (m
The concentration limit of R410A which is used in air conditioner is 0.3 kg/m

For your safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong
from the power cord.

Electrical Information

Be sure the electrical service is adequate for the model you have chosen. This information can be found on
the serial plate, which is located on the side of the cabinet.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is
against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to
use is not an equately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician
to install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.
Do not run air conditioner with outside protective cover in place. This could result in mechanical damage within
the air conditioner.

Working temperature range

Outdoor side temperature
Cooling Operation
Indoor side temperature
Safety Precautions
EN
3
)
3
)
3
.
06