DANGER
ING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided
with this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily
injury, or loss of life. Only persons who can follow and understand these instructions should operate
or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact
Pinnacle Climate Technologies at 800-641-6996.
DANGER
ING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION,
ALTERATION OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within
the area in which it is used. Failure to provide adequate combustion and ventilation air will result in
asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 7.
U.S. Patent No. 9,644,863
FACTORY ID: 001
MODEL NUMBERS:
MH-150T-SDR / MH-220T-SDR
GENERAL HAZARD WARNING: READ AND UNDERSTAND ALL OF
THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, START-
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED
SPACES WITHOUT ADEQUATE VENTILATION. FOR OUTDOOR USE.
INDOOR USE PERMITTED ONLY FOR: THE TEMPORARY HEAT-
Fax: 320-251-2922 • Web:
SilentDrive
FORCED AIR HEATER
®
User's Manual &
Operating Instructions
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free
www.masterindustrialproducts.com
© 2018 Pinnacle Climate Technologies, Inc.
(800) 641-6996
• Email: info@pinnacleclimate.com
MASB-407

Advertisement

Table of Contents
loading

Summary of Contents for Master SilentDrive MH-220T-SDR

  • Page 1 SilentDrive FORCED AIR HEATER ® User’s Manual & Operating Instructions MODEL NUMBERS: MH-150T-SDR / MH-220T-SDR CONSUMER: READ AND SAVE THESE INSTRUCTIONS Locating Your Serial Number: Your serial number can be found on a white label on the right side cover of your heater. For Example: 123456789.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TABLE OF CONTENTS Safety Information............2-3 Maintenance..............8-9 What’s in the Box.............4 Wiring Diagram...............10 Specifications..............4 Troubleshooting Guide..........11 Features................5 Exploded View..............12 Ventilation................6 Parts List..............12-13 Operation..............6-7 Limited Warranty............14 SAFETY INFORMATION FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep com- WARNING bustibles such as;...
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE SAFETY INFORMATION (CONT.) RISK OF INDOOR WARNING RISK OF ELECTRIC WARNING AIR POLLUTION! SHOCK! The products described in this manual are kero- sene direct-fired, forced air heaters. Kerosene ALWAYS use only the electrical power (voltage and forced air heaters are primarily intended for use frequency) specified on the model plate of the heater.
  • Page 4: What's In The Box

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WHAT’S IN THE BOX Tools Needed: Tip: Be sure to remove the axle from the side of the Styrofoam packaging. - Phillips head screw driver - 8 mm open end wrench Tip: Use a power screwdriver and locking - 19 mm open end wrench wrench for easier assembly.
  • Page 5: Features

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE FEATURES Shell Control Panel Rear Guard Handle Power Cord Support Frame Wheel Fuel Gauge Fuel Cap Fuel Tank Drain Bolt ASSEMBLY INSTRUCTIONS Models: 150T-SDR / 220T-SDR 1. Insert axle through holes in wheel support. 2.
  • Page 6: Ventilation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE VENTILATION - Risk of indoor air pollution and Carbon Monoxide Poisoning. Not For Indoor Use. Indoor use permitted only for the temporary heating of buildings under construction, alteration or repair. - Refer to Safety Information on page 3 for information about Carbon Monoxide Poisoning.
  • Page 7: Operation

    SDR 220 Rating Label + Control Panel NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Model - Modelo MH-220T-SDR OPERATION (CONT.) BTU/Hr - BTU/h 220,000 Fuel Consumption Gal./Hr. 1.67 Consumo de Combustible Gal./h Fuel Tank Capacity Gal. Capacidad del Depósito Gal.
  • Page 8: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE MAINTENANCE Long Term Storage: Service: Drain fuel through the drain bolt in the bottom of DO NOT TAMPER WITH THE UNIT. HAVE A the fuel tank. COMPETENT SERVICEMAN MAKE ANY NECESSARY 2.
  • Page 9 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance FUEL FILTER: PHOTOCELL: The fuel filter should be cleaned at least twice The photocell should be cleaned using a cotton per heating season. Clean the filter by rinsing swab dipped in alcohol or water at least once per it in clean K-1 Kerosene.
  • Page 10: Wiring Diagram

    AC 250V / 3.15A NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAM DFV Wiring Diagram 1. Igniter 2. Pump 3. Motor 4. Condensor 5. Limit Control 6. Dump 7. PCB Assembly 8. Thermistor 9.
  • Page 11: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TROUBLESHOOTING GUIDE Problem Possible Cause Solution Heater Ignites, but main PCB shuts Dirty fuel filter. Clean / replace fuel filter. off after a short period of time. 2.
  • Page 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 34 35 PARTS LIST Item # Description 150T-SDR 220T-SDR Combustion Chamber 70-011-1000 70-011-1010 Main Power PCB 70-027-2005 70-027-2005 Power PCB Case 70-027-1250 70-027-1250 PCB Lead Wire 70-027-1025 70-027-1025 Nozzle...
  • Page 13 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE PARTS LIST Item # Description 150T-SDR 220T-SDR Limit Control Bracket 70-019-1010 70-019-1010 Photocell 70-016-1000 70-016-1000 Photocell bracket 70-016-0101 70-016-0101 Air Draft Tube 70-300-0001 70-300-0001 Duct Bracket 70-300-0020 70-300-0020 Sirroco Fan 70-060-0001...
  • Page 14: Limited Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater to If Pinnacle Climate Technologies, Inc. finds the item to the original retail purchaser only, to be free from defects in be in normal operating condition, or not defective the item material and workmanship for a period of one (1) year from will be returned freight collect.
  • Page 15 CHAUFFERETTE À AIR FORCÉ SilentDrive ® Manuel de l’utilisateur et mode d’emploi NUMÉROS DE MODÈLES : MH-150T-SDR/MH-220T-SDR NOTE AU CLIENT : LIRE ET CONSERVER CE MANUEL POUR CONSULTATION ULTÉRIEURE Repérage du numéro de série : Le numéro de série se trouve sur une étiquette blanche apposée du côté droit de la chaufferette. Par exemple : 123456789. Noter le numéro de série avant de contacter le service à...
  • Page 16 NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. TABLE DES MATIÈRES Consignes de sécurité ..........2-3 Entretien ..............8-9 Contenu de la boîte ............4 Schémas de câblage ...........10 Spécifications ..............4 Guide de dépannage ...........11 Caractéristiques .............
  • Page 17: Consignes De Sécurité

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. CONSIGNES DE SÉCURITÉ (SUITE) AVERTISSEMENT AVERTISSEMENT RISQUE DE DÉCHARGE ÉLECTRIQUE! RISQUE DE POLLUTION DE L’AIR INTÉRIEUR! Les produits décrits dans ce manuel sont des chaufferettes TOUJOURS utiliser uniquement l’alimentation électrique à...
  • Page 18: Contenu De La Boîte

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. CONTENU DE LA BOÎTE Outils nécessaires : CONSEIL : Retirer l’essieu par le côté de l’emballage de polystyrène. - Tournevis cruciforme - Clé à fourche de 8 mm CONSEIL : Pour un assemblage plus facile, utiliser - Clé...
  • Page 19: Caractéristiques

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. CARACTÉRISTIQUES Enveloppe Commande panneau Protecteur arrière Poignée Cordon électrique Châssis de support Roulette Jauge de carburant Bouchon du Réservoir de Bouchon de vidange réservoir de carburant carburant...
  • Page 20: Ventilation

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. VENTILATION - Risque de pollution de l’air intérieur et d’empoisonnement au monoxyde de carbone. Ne pas utiliser à l’intérieur. L’usage à l’intérieur n’est autorisé que pour le chauffage temporaire des bâtiments en cours de construction, de modification ou de réparation. - Se reporter aux instructions de sécurité...
  • Page 21 SDR 220 Rating Label + Control Panel NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. Model - Modelo MH-220T-SDR MODE D’EMPLOI (SUITE) BTU/Hr - BTU/h 220,000 Fuel Consumption Gal./Hr. 1.67 Consumo de Combustible Gal./h Fuel Tank Capacity Gal.
  • Page 22 NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. ENTRETIEN Entreposage de longue durée : Réparation : Vidanger le réservoir de carburant au moyen du boulon NE PAS MODIFIER L’APPAREIL. TOUT AJUSTEMENT OU de vidange situé...
  • Page 23: Entretien

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. Entretien FILTRE À CARBURANT : CELLULE PHOTOÉLECTRIQUE : Les pales doivent être nettoyées au moins une fois par La cellule photoélectrique doit être nettoyée à l’aide d’un saison de chauffage, ou plus fréquemment selon l’état.
  • Page 24: Schémas De Câblage

    AC 250V / 3.15A NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. SCHÉMA DE CÂBLAGE DFV Wiring Diagram 1. Allumeur 2. Pompe 3. Moteur 4. Condensateur 5. Limiteur 6. Vidange 7. Carte de circuits imprimés 8.
  • Page 25: Guide De Dépannage

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. GUIDE DE DÉPANNAGE Problème Cause possible Solution La chaufferette s’allume, mais la Filtre à carburant sale. Nettoyer/remplacer le filtre à carburant. carte de circuits imprimés principale 2.
  • Page 26: Vue Éclatée

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. VUE ÉCLATÉE 34 35 LISTE DES PIÈCES de réf. Description 150T-SDR 220T-SDR Chambre de combustion 70-011-1000 70-011-1010 Circuit d’alimentation principal 70-027-2005 70-027-2005 Boîtier du circuit d’alimentation 70-027-1250 70-027-1250 Fil du circuit d’alimentation...
  • Page 27 NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. LISTE DES PIÈCES de réf. Description 150T-SDR 220T-SDR Support du limiteur 70-019-1010 70-019-1010 Cellule photoélectrique 70-016-1000 70-016-1000 Support de cellule photoélectrique 70-016-0101 70-016-0101 Tube d’aspiration d’air 70-300-0001 70-300-0001...
  • Page 28: Garantie Limitée

    NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU’ELLE BRÛLE OU QU’ELLE EST BRANCHÉE À UNE SOURCE D’ALIMENTATION. GARANTIE LIMITÉE Pinnacle Climate Technologies, Inc. garantit à l’acheteur Si Pinnacle Climate Technologies, Inc. détermine que au détail d’origine seulement que cette chaufferette sera l’article est dans un état d’utilisation normale, ou n’est pas exempte de défauts de matériau et de fabrication pendant défectueux, il sera retourné...
  • Page 29 CALENTADOR DE AIRE FORZADO Silent Drive ® Manual del usuario e Instrucciones de operación MODELOS N.° MH-150T-SDR / MH-220T-SDR CONSUMIDOR: LEA Y CONSERVE ESTAS INSTRUCCIONES Cómo localizar su número de serie: El número de serie lo puede encontrar en una etiqueta blanca en el lado derecho de la cubierta de su calentador. Por ejemplo: 123456789.
  • Page 30 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN ÍNDICE Información de seguridad ........2-3 Mantenimiento ............8-9 Qué hay en la caja ............4 Diagrama eléctrico ............10 Especificaciones ............4 Guía para la solución de problemas ......11 Características ..............
  • Page 31: Información De Seguridad

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN INFORMACIÓN DE SEGURIDAD (CONTINÚA) ¡RIESGO DE ADVERTENCIA ADVERTENCIA DESCARGA ELÉCTRICA! ¡RIESGO DE CONTAMINACIÓN DEL AIRE INTERIOR! SIEMPRE utilice la energía eléctrica (voltaje y frecuencia) que Los productos descritos en este manual son calentadores se indica en la placa de modelo del calentador.
  • Page 32: Qué Hay En La Caja

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN QUÉ HAY EN LA CAJA Herramientas necesarias: CONSEJO: Asegúrese de retirar el eje del lateral del empaque de espuma de poliestireno. - Destornillador Phillips - Llave plana de 8 mm CONSEJO: Use un destornillador eléctrico y una - Llave plana de 19 mm...
  • Page 33: Características

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN CARACTERÍSTICAS Coraza Tablero de control Protección trasera Cable eléctrico Bastidor de soporte Rueda Indicador de Tapa de Tanque de Perno de drenaje combustible combustible combustible INSTRUCCIONES DE ARMADO...
  • Page 34: Ventilación

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VENTILACIÓN - Riesgo de contaminación del aire interior y de envenenamiento por monóxido de carbono. No debe usarse en interiores. El uso en interiores sólo se permite para la calefacción temporal de edificios en construcción, modificación o reparación.
  • Page 35 SDR 220 Rating Label + Control Panel NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Model - Modelo MH-220T-SDR FUNCIONAMIENTO (CONTINÚA) BTU/Hr - BTU/h 220,000 Fuel Consumption Gal./Hr. 1.67 Consumo de Combustible Gal./h Fuel Tank Capacity Gal.
  • Page 36: Mantenimiento

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN MANTENIMIENTO Almacenamiento a largo plazo: Servicio: Drene el combustible a través del perno de drenaje que NO ALTERE LA UNIDAD. PIDA A UN TÉCNICO COMPETENTE está...
  • Page 37 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento FILTRO DE COMBUSTIBLE: FOTOCÉLULA: El filtro de combustible debe limpiarse al menos dos veces La fotocélula debe limpiarse con hisopo de algodón por cada temporada de calefacción.
  • Page 38: Diagrama Eléctrico

    AC 250V / 3.15A NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN DIAGRAMA ELÉCTRICO DFV Wiring Diagram 1. Encendedor 2. Bomba 3. Motor 4. Condensador 5. Control de limite 6. Vertedero 7.
  • Page 39: Guía Para La Solución De Problemas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GUÍA PARA LA SOLUCIÓN DE PROBLEMAS Problema Posible causa Solución El calentador se enciende, pero la Filtro de combustible sucio. Limpie o reemplace el filtro placa de circuitos impresos principal de combustible.
  • Page 40: Vista Detallada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VISTA DETALLADA 34 35 LISTA DE PIEZAS Pieza # Descripción 150T-SDR 220T-SDR Cámara de combustión 70-011-1000 70-011-1010 Placa de circuitos impresos (PCI) principal 70-027-2005 70-027-2005 Caja de la placa de circuitos impresos...
  • Page 41 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN LISTA DE PIEZAS Pieza # Descripción 150T-SDR 220T-SDR Soporte del control de límite 70-019-1010 70-019-1010 Fotocélula 70-016-1000 70-016-1000 Soporte de la fotocélula 70-016-0101 70-016-0101 Tubo de Caudal de Aire 70-300-0001...
  • Page 42: Garantía Limitada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este Si Pinnacle Climate Technologies, Inc. descubre que el calentador únicamente al comprador minorista original, artículo está en condiciones normales de funcionamiento como libre de defectos en materiales y mano de obra o que no está...

This manual is also suitable for:

Silentdrive mh-150t-sdr

Table of Contents