- Risk of indoor air pollution and Carbon Monoxide Poisoning. Not For Indoor Use. Indoor use permitted
only for the temporary heating of buildings under construction, alteration or repair.
- Refer to Safety Information on page 3 for information about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space of at least three square feet (2,800 sq. cm) for each 100,00
Btu/Hr. (29 kW) of heater output. Provide a larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
150T-SDR
5.3 ft.²
3760 cm²
Fueling The Heater:
Kerosene (K-1)
For optimal performance of this heater, it is strong-
ly suggested that K-1 kerosene be used. K-1 kero-
sene has been refined to virtually eliminate con-
taminants, such as sulfur, which can cause a rotten
egg odor during the operation of the heater. Using
diesel fuel can cause excess soot production. Do
not use Bio-Diesel as this fuel will damage your
heater's seals and filter.
- CSA certified for use with K-1 kerosene,
no. 1 diesel, Jet A Fuel, no. 1 fuel oil.
DO NOT use any fuel that is not approved above.
- NEVER use fuel such as, benzene, alcohol, white glass,
camp stove fuel, paint thinners, farm diesel, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR EXPLOSION.
- NEVER store kerosene in the living space. Kerosene
should be stored in a well ventilated area outside
the living area.
- NEVER store kerosene in direct sunlight or near a
source of heat.
- NEVER use kerosene that has been stored from one
season to the next. Kerosene deteriorates over time.
OLD KEROSENE WILL NOT BURN PROPERLY IN
THIS HEATER.
NOTE: Kerosene should only be stored in a blue con-
tainer that is clearly marked "Kerosene." Never store
kerosene in a red container. Red is associated with
gasoline.
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE

VENTILATION

220T-SDR
6.5 ft.²
5990 cm²
OPERATION
OR OPERATING. FIRE OR EXPLOSION
COULD RESULT.
FILL THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN
FUELING, AND NEVER OVERFILL THE
TANK.
6
DANGER
DANGER
WARNING
CAUTION
Silent Drive Forced Air Heater User's Manual
CARBON MON-
OXIDE POISON-
ING MAY LEAD TO
DEATH!
NEVER REFUEL
THIS HEATER
WHILE IT IS HOT
DO NOT USE GAS-
OLINE OR CRANK-
CASE DRAININGS.
NEVER FILL THE
FUEL TANK IN-
DOORS. ALWAYS

Hide quick links: