Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 6 feet long and is a minimum of 14
AWG rating.
4. Press the power button to power on the
heater (see Figure 3).
5. Select desired temperature using temperature
+/- buttons.
6. The heater will ignite once the temperature
setting is higher than the ambient
temperature in the space.
Stopping / Restarting Heater:
To stop the heater, move the power switch to
-
the "Off" position and unplug the power cord.
To restart the heater; wait 10 seconds and
-
follow ignition steps.
Adjusting the Pump Pressure:
Remove the right side cover (4 screws). Behind
-
the panel, the pump will have a brass screw.
Turn screw in quarter turn increments.
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
-
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
temperature to a higher setting until the heater
ignites.
steps 1-3 above and press power button to
power ON the heater.
7
SDR 220 Rating Label + Control Panel
Model - Modelo
BTU/Hr - BTU/h
Fuel Consumption Gal./Hr.
Consumo de Combustible Gal./h
Fuel Tank Capacity Gal.
Capacidad del Depósito Gal.
Pump Pressure PSI - Presión de le Bomba
V~Hz/Amps - V~Hz/Amperes
TIP: If the heater does not ignite, the
Fuse - Fusible
Phase - Fase
thermostat may be set too low. Increase the
Type of Fuel
Tipo de aceite combustible
Maximum Air Outlet Temp. °F
Max. Temp. Del Aire De Salida °C
Minimum Distance From Combustibles:
Outlet: 8 ft. (250 cm) Sides / Top / Rear: 4 ft. (125 cm)
Minimas Distancias de Separacion de Materiales
TIP: If the heater does not ignite; press
Combustibles:
Salida de Aire: 8 ft. (250 cm)
power button to power off the heater, check
Lateral / Superior / Posterior: 4 ft. (125 cm)
See Operating Instructions and Troubleshooting on
side panel.
Las instrucciones de Funcionamiento y soluciónes
de problemas se encuentran en el panel lateral.
COMPLIES WITH UL 733 AND
CSA-B140.0-03 AND CSA B140.8-1967
© 2018 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com
°F
Figure 3
Silent Drive Forced Air Heater User's Manual
MH-220T-SDR
220,000
1.67
13
123
120V~60Hz / 3.15
3.15A
No. 1 / Kerosene
No. 1 / Queroseno
1025
552
Made In China
Hecho en China
°F
MASD-007