Bock Water heaters 32E Installation, Operation & Maintenance Instructions Manual

Bock Water heaters 32E Installation, Operation & Maintenance Instructions Manual

Residential oil-fired water heaters
Table of Contents

Advertisement

Available languages

Available languages

TO THE INSTALLER:
Please attach these in -
struc tions next to the
water heater.
TO THE CONSUMER:
Read these and all com -
po nent in struc tions.
Please keep for fu ture
reference. Please re -
mem ber to return the
registration card.
Waranty, registration
card & parts list in clud ed.
WARNING:
Improper installation, adjustment, alteration, ser vice
or maintenance can cause serious in ju ry or prop -
erty damage. Refer to this man u al. For as sis tance
or additional in for ma tion, con sult a qual i fied in stall er
or service agency.
WARNING:
If the information in these instructions is not fol -
lowed exactly, fire or explosion may result and can
cause property damage, personal in ju ry or death.
WARNING:
Follow minimum combustible clearance as noted
on wa ter heater label. Do not in stall on com bus ti -
ble flooring (see Figure 2, Page 3). In stall in ac cor -
dance with all lo cal codes. In the ab sence of local
codes, re fer to NFPA 31.
CAUTION:
The recommended temperature for normal residen -
tial use is 120°F. The dial on the aquastat does not
always reflect the outcoming water tem per a ture,
which could occasionally exceed 120°F. The vari a -
tion in outcoming tem per a ture could be based on
factors including but not limited to us age pat terns
and type of installation. Test your water at the tap
nearest to the water heater. (See page 5 for mea -
sur ing the outcoming water tem per a ture).
23420
Phone: 608/257-2225 • Fax: 608/257-5304 • www.bockwaterheaters.com
BOCK RESIDENTIAL OIL-FIRED
Model numbers: 32E, 32PPC, 33E, 50ES,
51EC, 51PPC, 120E
Bock Water Heaters, Inc.
110 South Dickinson Street • Madison, WI 53703
INSTALLATION, OPERATION &
MAINTENANCE IN STRUC TIONS
WATER HEATERS
WARNING:
Hotter water increases the risk of scald injury. Be -
fore changing the temperature setting, read the
in struc tion manual. Tem per a tures at which injury oc -
curs vary with the in di vid u al's age and length of
ex po sure.
The slower reaction times of children, elderly and
physically or mentally impaired persons in creas es
the scald ing hazard to them. It is rec om mend ed low er
wa ter temperatures be used where these sit u a tions
exist.
Households with small children or invalids may re -
quire a tem per a ture setting less than 120°F to pre vent
accidental contact with hot water.
To lower water temperature use point-of-use tem -
per a ture limiting devices.
WARNING:
Flammable vapors may be drawn to this wa ter heat -
er from other areas of the struc ture by air currents.
Do not store or use any flam ma ble liquids in the
vicinity of this heater.
WARNING:
Water heater blankets may not be used on the
heater and may cause fire, asphyxiation, per son al
injury or death.
Rev 10 (9/17)

Advertisement

Table of Contents
loading

Summary of Contents for Bock Water heaters 32E

  • Page 1 Please keep for fu ture WATER HEATERS reference. Please re - mem ber to return the registration card. Model numbers: 32E, 32PPC, 33E, 50ES, Waranty, registration 51EC, 51PPC, 120E card & parts list in clud ed. WARNING: WARNING: Improper installation, adjustment, alteration, ser vice Hotter water increases the risk of scald injury.
  • Page 3 DO NOT INSTALL THE WATER HEATER ON COMBUS- TIBLE FLOORING (see Figure 2). Refer to NFPA 31 or contact Bock Water Heaters with questions concerning Check for exhaust fans in proper flooring materials.
  • Page 4: Connect Water Piping

    Connect the water piping, being careful not to apply heat to the heater CONNECT WATER nipples. Install dielectric unions and shut off valves on both hot and cold water PIPING lines. Model 33E is equipped with an inlet flow diverter installed in the tank.
  • Page 5: Connect The Electricity

    CONNECT THE All wiring must comply with applicable codes and ordinances. The primary relay is wired to the burner at the factory. Install the aquastat well in the 3/4" tapping at ELECTRICITY the front of the heater. Be sure the sensing bulb is inserted all the way into the well.
  • Page 6: Maintenance

    2. To place burner in operation, follow the instructions provided with the burner. 3. Set the pump pressure to 100 PSI for Wayne, Carlin and Beckett burners and 150 PSI for Riello burners. 4. Adjust the burner combustion air in accordance with the burner manufacturer’s Warning: Handhole instructions.
  • Page 7 WIRING FIGURE 4 FIGURE 5 : Carlin burner w/ Carlin EZ-Temp : Beckett or Wayne burner w/ Carlin EZ-Temp For Models: 32, 33, 50, 51, 120 For Models: 32, 33, 50, 51, 120 (see burner manufacturer’s instructions for 20e; 60200 primary w/ three wire harness) FIGURE 6 FIGURE 7 : Honeywell L4103A-1142...
  • Page 8 Immersion Well & Aquastat Drain Valve Mounting Bracket Gasket 10. Burner Mounting Bracket (part of jacket assembly on Models 32E through 51 Series; sold sep a rate ly on 120E) 11. Bottom Pan 12. Combustion Chamber Sleeve 13. Combustion Chamber 14.
  • Page 9: What Does This Limited Warranty Cover

    LIMITED WARRANTY FOR OIL-FIRED WATER HEATER Bock Water Heaters, Inc. 110 S. Dickinson Street Madison, WI 53703 Phone: 608-257-2225 WHAT DOES THIS LIMITED WARRANTY COVER? This limited warranty applies only to the original consumer purchaser. General Defects and Malfunctions: This warranty covers defections and malfunctions in your new water heater for a period of one year from the original installation date.
  • Page 10 WHETHER ARISING IN CONTACT OR TORT. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. Bock Water Heaters, Inc. • 110 South Dickinson Street • Madison, WI 53703 Telephone 608-257-2225 • Fax 608-257-5304 www.bockwaterheaters.com...
  • Page 11 CHART A BOCK BURNER MODEL/ MODEL MODEL (OIL) MFR. OEM # INPUT OEM # INPUT UL LISTED BURNERS 32E, 32EC, 33E WAYNE MSR/371-001B 0.75 X 80A 32PP, 32PPC WAYNE HS/371-009HS 0.75 X 80A WAYNE MSR/371-030B 0.90 X 70A 5IE, 51EC...
  • Page 12 – 11 –...
  • Page 13 BOCK AU MAZOUT ultérieure. N’oubliez pas de nous renvoyer fiche d’enregistrement. Numéros de modèle : 32E, 32PPC, 33E, Pièces incluses : garantie, 50ES, 51EC, 51PPC, 120E fiche d’enregistrement du produit et liste des pièces. AVERTISSEMENT : AVERTISSEMENT : Une installation, un réglage, une modification, un...
  • Page 14 PLANCHER COMBUSTIBLE (voir la figure 2). Référez-vous Vérifiez qu’il n’y a pas de ventilateurs de à la norme NFPA 31 ou contactez Bock Water Heaters pour tirage dans la pièce où se trouve le toute question concernant les matériaux qui conviennent au chauffe-eau ou à...
  • Page 15 Raccordez la tuyauterie d’eau en veillant à ne pas chauffer les mamelons du chauffe-eau. RACCORDEZ LA Installez les raccords diélectriques et les robinets d’arrêt sur canalisations d’eau chaude TUYAUTERIE D'EAU et froide. Modèle 33E est munis d’une dérivation du débit d’entrée installée dans le réservoir.
  • Page 16 Examinez la conduite d’arrivée d’eau pour voir s’il existe des clapets de non-retour ou des réducteurs de pression. Tout type de clapet de non-retour risque d’entraîner une augmentation de la pression à l’intérieur du chauffe-eau et par conséquent une panne. Si le chauffe-eau est installé sur un circuit fermé...
  • Page 17 Système d’élévation : il faut commander le brûleur avec une pompe à deux étages. Mettez en place un système à deux conduites (canalisations d’aspiration et de retour). Installez le bouchon de dérivation selon les instructions fournies avec la pompe (le bouchon se trouve dans le sac qui contient les instructions).
  • Page 18 4. Le réglage de l’air de combustion du brûleur doit se faire conformément aux instructions du fabricant. L’utilisation d’appareils d’analyse de la combustion pour vérifier le CO2 et la fumée. La teneur en C02 doit être d’au moins 11 % avec un indice de noircissement de 0 sur l’échelle de Bacharach.
  • Page 19 CÂBLAGE FIGURE 4 : Brûleur Carlin avec Carlin EZ-Temp FIGURE 5 : Brûleur Beckett ou Wayne avec Carlin EZ-Temp Pour les modèles : 32, 33, 50, 51, 120 Pour les modèles : 32, 33, 50, 51, 120 (Consultez les instructions du fabricant pour le 20e; 60200 principal avec un faisceau de trois câbles) 120 vac/1-PHASE/60-HZ avec fusible de 15...
  • Page 20 Robinet de purge Joint du support de montage 10. Support de montage du brûleur (fait partie de l’enveloppe des modèles 20e et des modèles des séries 32E jusqu’à 51; vendu séparément sur les modèles 120E) 11. Assise 12. Enveloppe de la chambre de combustion 13.
  • Page 21: Garantie Limitée

    Cette garantie recouvre les chauffe-eau « Bock » modèles 20e, 20pp, 32E, 32EC, 32PP , 32PPC, 33E, 33PP , 40E, 40PP , 50ES, 50ESC, 51E, 51EC, 51PP , 51PPC, 71E et 120E. Bock Water Heaters, Inc., une filiale de Bock Corporation – incorporée aux États-Unis d’Amérique dans le Wisconsin –...
  • Page 22 à couvrir de la garantie de l’équipement d’origine. Le propriétaire prendra les dispositions qui s’imposent pour l’inspection annuelle des barres d’anode. Bock Water Heaters, Inc. exige des reçus pour preuve de paiement de la maintenance des anodes en cas de réclamation concernant un réservoir vitrifié.
  • Page 24 Bock Water Heaters, Inc. 110 South Dickinson Street • P.O. Box 8632 • Madison, WI 53708-8632 – États-Unis Tél : 608/257-2225 • Télécopieur : 608/257-5304 • www.bockwaterheaters.com...

This manual is also suitable for:

32ppc50es51ec33e51ppc120e

Table of Contents