Bock Water heaters 72E Installation, Operation & Maintanance Manual

Bock Water heaters 72E Installation, Operation & Maintanance Manual

Oil-fired water heaters

Advertisement

TO THE INSTALLER:
Please attach these in-
structions next to the
water heater.
TO THE CONSUMER:
Read these and all
component
instruc-
tions. Please keep for
future reference.
Waranty, registration card
& parts list in clud ed.
WARNING: Improper installation, adjustment, al ter ation,
ser vice or main te nance can cause se ri ous in ju ry or
prop er ty dam age. Refer to this man u al. For as sis tance
or ad di tion al in for ma tion, con sult a qualified in stall er or
ser vice agen cy.
WARNING: If the information in these instructions is not
fol lowed exactly, fire or explosion may result and can
cause prop er ty damage, personal in ju ry or death.
DO NOT INSTALL THE WATER HEATER ON COMBUSTI-
Install in ac cor dance with all local
BLE FLOORING.
codes. In the ab sence of local codes, refer to NFPA 31
or ANSI Z21.10.1,
or contact Bock Water Heaters with
questions concerning proper flooring materials.
Minimum clearance to combustible construction is:
SIDES 6"; BACK 6"; FRONT 24". The installation of this
water heater must conform with local codes and ordi-
nances. In the absence of local codes, the installation
must comply with the National Fire Protection Associa-
tion (NFPA 31) Code.
WARNING: The recommended temperature for nor mal
res i den tial use is 120
not always re flect the outcoming water temperature,
110 S. Dickinson St. • P.O. Box 8632 • Madison, WI 53708-8632
Phone: 608/257-2225 • Fax: 608/257-5304 • www.bockwaterheaters.com
– 1 –
23400
& MAINTENANCE INSTRUCTIONS
OIL-FIRED WATER HEATERS
F. The dial on the aquastat does
o
Bock Water Heaters, Inc.
INSTALLATION, OPERATION
72E • 361E • 541E
which could oc ca sion al ly ex ceed 120 o F. The vari a tion in
outcoming tem per a ture could be based on factors in -
clud ing but not lim it ed to usage pat terns and type of
in stal la tion. Test your water at the tap nearest to the wa -
ter heat er.
WARNING: Hotter water increases the risk of scald in -
ju ry. Be fore changing the temperature set ting, read the
in struc tion manual. Tem per a tures at which injury oc curs
vary with the in di vid u al's age and length of ex po sure.
The slower reaction times of children, elderly and phys -
i cal ly or mentally impaired persons in creas es the
scald ing hazard to them. It is rec om mend ed low er wa -
ter tem per a tures be used where these sit u a tions exist.
To lower water temperature use point-of-use tem-
perature limiting devices.
WARNING: Flammable vapors may be drawn to this
wa ter heat er from other areas of the struc ture by air cur -
rents. Do not store or use any flammable liquids in
the vicinity of this heater.
WARNING: Water heater blankets may restrict air flow
to the heat er and cause fire, asphyxiation, per son al in -
ju ry or death.
WARNING: Hydrogen gas can be produced in a hot
water system that has not been used for an extended
period–gen er al ly, two weeks or longer. To prevent pos-
sible injury under this situation, we recommend that a
hot water faucet be wide open for several minutes
before you use ANY electrical appliance that is con nect -
ed to the hot water system. If hydrogen is present, an
unusual sound – such as air escaping – will come from
the open faucet as the hot water begins to flow.
Hydrogen gas is extremely flammable – there must
be no open flame near this open faucet.
Rev 8 9/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 72E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bock Water heaters 72E

  • Page 1 Please keep for future reference. OIL-FIRED WATER HEATERS 72E • 361E • 541E Waranty, registration card & parts list in clud ed. which could oc ca sion al ly ex ceed 120 o F. The vari a tion in...
  • Page 2 ” 3/4” 1 ” 361E 67” ” 26” 23” 9” 2”* 1” 3/4” 2” 361E 541E 541E 66” 34” ” NA 10” 2”* 2”* 3/4” 2” * Nipple not furnished ** Under drain valve – 2 – on 72E only...
  • Page 3: Combustion And Ventilation Air

    WATER PIPING: Models 72E and 361E have dip tubes. When using sweat fit tings, do not apply attention to avoid heat to the nipples. Pipe hot and cold lines with a union and valve on each line.
  • Page 4: Electric Wiring

    Wiring must be done in ac cor dance with the National Electrical Code and local or di nanc es. Burners are supplied with an operating thermostat (Honeywell L4103A or Carlin EZ-Temp 90000B on 72E, Honeywell L4006A or Carlin EZ-Temp 90000C or Carlin EZ-Temp 90300B on the 361E, and Honeywell L8100C or Carlin EZ-Temp 90300B on 541E).
  • Page 5 TANT! The water heater warranty will be invalid if the tank fails due to excessive pressure, the ac cu - mu la tion of lime or sediment, corrosion, or freezing. The Bock Water Heaters warranty (back page) explicitly doc u ments further causes of in vali da tion.
  • Page 6 FIGURE 4 FIGURE 3 Wayne WAYNE Model 72E Model 361E, 541E L4080B L8106 L4006A FIGURE 6 FIGURE 5 Wayne burner Carlin burner w/ w/ Carlin EZ-Temp Carlin EZ-Temp (all models) Models 72E, Beckett burner 361E, 541E with Carlin EZ-Temp (Only 72E)