Bock Water heaters EZ FIT Atmospheric Gas EZ 75-76N Instruction Manual

Bock Water heaters EZ FIT Atmospheric Gas EZ 75-76N Instruction Manual

Advertisement

Quick Links

To the Installer:
Please attach these instructions
next to the water heater.
!
WARNING
Improper installation, adjustment, alteration,
service or maintenance can cause serious
injury or property damage. Refer to this
manual. For assistance or additional
information, consult a qualified installer or
service agency.
!
WARNING
If the information in these instructions is not
followed exactly, a fire or explosion may result
causing property damage, personal injury or
death.
WARNING
!
Do not install on combustible flooring. Install
in accordance with all local codes. In the
absence of local codes, refer to ANSI
223.1/NFPA 54 and/or CSA B149.1.
!
CAUTION
The recommended temperature for normal
residential use is 120°F. The dial on the aquastat
does not always reflect the out-coming water
temperature and it could occasionally exceed
120°F. Variation in out-coming temperature
could be based on factors including but not
limited to usage patterns and type of installa-
tion. Test water at the tap nearest to the water
heater. See page 9 for measuring the out-
coming water temperature.
!
WARNING
Hotter water increases the risk of scald injury.
Before adjusting the water temperature setting,
read this instruction manual. Temperatures at
which injury occurs vary with the person's age
and the length of exposure. The slower
reaction time of children, elderly or physically
or mentally challenged persons increases the
scalding hazard to them. It is recommended
that lower water temperatures be used where
these exposure hazards exist. Households with
small children or invalids may require a
temperature setting less than 120°F to prevent
accidental contact with hot water. To produce
less than 120°F, use point-of-use
temperature limiting devices.
23405
To the Consumer:
Please read these and all component
instructions and keep for future reference.
Atmospheric Gas Instruction Manual
Warranty, Registration Card and Parts List are included.
Homeowner: Please remember to return the Registration Card!
If higher water temperature is needed in part
of the water system, automatic temperature
limiting devices must be used on all lines to
water taps.
Flammable vapors may be drawn to this water
heater from other areas of the structure by air
currents. Do not store or use any flammable
liquids in the vicinity of this heater.
Water heater blankets may restrict air flow to
the water heater and cause fire, asphyxiation,
personal injury or death.
Read all instructions thoroughly before
attempting installation or operation of your
water heater. Keep these instructions for future
reference.
Local plumbing and electrical codes must be
followed in the installation of this water
heater. In the absence of a local code use the
UNIFORM PLUMBING CODE and the NFPA
Code. Local codes may supersede instructions
in this installation manual.
These instructions are a guide for the correct
installation of the water heater. The manufac-
turer will not be liable for damages caused by
failure to comply with the installation and
operating instructions outlined on the
following pages.
Installation, testing, and replacement of gas
piping, appliances, or accessories, and repair
and servicing of equipment, shall be
performed only by a qualified agency.
EZ 75-76, EZ 100-76
WARNING
!
!
WARNING
THIS MANUAL HAS BEEN PREPARED TO
ACQUAINT YOU WITH THE INSTALLATION,
OPERATION, AND MAINTENANCE OF YOUR
WATER HEATER AND TO PROVIDE IMPORTANT
SAFETY INFORMATION.
FAILURE TO FOLLOW THESE INSTRUCTIONS
OR ALL APPLICABLE BUILDING CODES
AND REGULATIONS VOIDS THE WARRANTY
ON THIS WATER HEATER.
Rev4 6/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EZ FIT Atmospheric Gas EZ 75-76N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bock Water heaters EZ FIT Atmospheric Gas EZ 75-76N

  • Page 1 To the Installer: To the Consumer: Please attach these instructions Please read these and all component next to the water heater. instructions and keep for future reference. Atmospheric Gas Instruction Manual EZ 75-76, EZ 100-76 Warranty, Registration Card and Parts List are included. Homeowner: Please remember to return the Registration Card! If higher water temperature is needed in part WARNING...
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY! - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Section I: Specifications ..........4 Section II: General Information.
  • Page 4: Section I: Specifications

    SECTION I: SPECIFICATIONS Cold Anode Rod (2) Draft Hood T&P Relief Valve Gas/Temp. Control WARNING READ ALL INSTRUCTIONS BEFORE LIGHTING WARM CAUTION HOTTER WATER INCREASES THE RISK OF SCALDING INJURY Drain Figure 1: All Models Table 1: Dimensions DIMENSIONS (inches) Model EZ 75-76N 133 69.19 65.38 26.00 58.25 14.50 11.00 4.00...
  • Page 5: Section Ii: General Information

    SECTION II: GENERAL INFORMATION WHEN YOU RECEIVE YOUR NEW WATER HEATER Check the new equipment to see if all components are in good condition. If damage is observed or parts appear to be missing, contact your wholesaler. WATER TREATMENT/FILTRATION In areas where poor water conditions are suspected (i.e. lime, iron, and other minerals), it is essential that the water be tested and appropriate action taken to prevent damage to the water heater and ensure the quality of the water.
  • Page 6 SECTION II: GENERAL INFORMATION (cont.) ANODE RODS The anode rod is used as a sacrificial element within the volume of the storage tank. The purpose of the magnesium anode rod is to protect the inside of the tank against corrosion. Anode rods should be inspected twice in the first year and at least yearly once a time interval for inspection has been developed.
  • Page 7: Section Iii: Pre-Installation

    SECTION II: GENERAL INFORMATION (cont.) BACKFLOW PREVENTER (CLOSED SYSTEM) Some local municipal codes and ordinances require the use of these devices on potable (domestic) water lines. Where backflow preventers are required, it will be necessary to install a thermal expansion tank (designed for use with potable water) in order to prevent pressure build up in the water heater and associated piping, which could cause the T&P valve to discharge.
  • Page 8 Figure 2 officials before using this method. Please consult local codes, NFPA 54 and/or contact Bock Water Heaters with questions concerning proper flooring materials. Leave adequate room for periodic maintenance of heater and burner. The water heater should be placed as near to the chimney as practical in order to keep vent connector length to a minimum.
  • Page 9 SECTION III: PRE-INSTALLATION (cont.) CONFINED SPACE (CONT.) B. Outside Air Supply: Confined spaces shall be provided with two permanent openings; one within 12 inches of the top and one within 12 inches of the bottom of the enclosure. These openings shall communicate directly, or by ducts, with the outdoors or spaces that communicate with the outdoors.
  • Page 10: Section Iv: Installation

    SECTION IV: INSTALLATION WATER CONNECTIONS CAUTION This water heater incorporates fittings that contain a nonmetallic lining. DO NOT apply heat to these fittings when making sweat connections to the heater. Sweat tubing to an adapter before securing adapter to any fittings on water heaters. ALL PIPING SHOULD CONFORM TO LOCAL CODES AND ORDINANCES.
  • Page 11 Do not use open flame. The pipe thread compound that is used on gas piping must be of the type resistant to propane gas. Do not use teflon tape on gas piping. Note: For high altitude applications (above 2000 feet) contact Bock Water Heaters. DRAFT HOOD AND VENTING This water heater must be installed with the factory supplied draft hood.
  • Page 12 SECTION IV: INSTALLATION (cont.) DRAFT HOOD INSTALLATION 1. Locate the two predrilled holes in the top pan. 2. Align and insert the draft hood legs (without screw holes) into the holes in the top pan. 3. Using a drill and the two sheet metal screws (supplied), fasten the other two legs (with screw holes) to the top pan.
  • Page 13: Section V: Operation

    SECTION V: OPERATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be If you cannot reach your gas supplier, call lighted by hand.
  • Page 14 SECTION V: OPERATION (cont.) INSPECT THE INSTALLATION AND ADJUST THE CONTROLS During the initial warm-up of the stored water, check for proper combustion by sampling combustion gas at a point just below the exit of the flue. O readings should be in the range of 4.5-5.0% with CO levels at 0 ppm.
  • Page 15: Section Vi: Maintenance

    SECTION VI: MAINTENANCE NOTICE TO THE OWNER: If you are having a mechanical problem with your water heater, contact your service company or installer. WATER PIPING On an annual basis, all piping should be checked for leakage at joints, shut-off valves, and unions.
  • Page 16: Section Vii: Troubleshooting

    SECTION VI: MAINTENANCE (cont.) INSPECT THE VENTING SYSTEM The vent system should be checked at least once a year for damage and blockage. A draft and combustion test is also recommended. If necessary, the water heater flue may be cleaned with a brush or flexible wire. Before proceeding: 1) Turn the gas valve OFF.
  • Page 17: Section Viii: Parts List

    SECTION VIII: PARTS LIST Figure 7: ezFIT Parts Table 4: ezFIT Parts P P a a r r t t D D e e s s c c r r i i p p t t i i o o n n Hot Outlet Nipple Gas Thermostat Anode Rods...
  • Page 18 SECTION VIII: PARTS LIST (cont.) Figure 8: ezFIT Burner Parts Table 5: ezFIT Burner Parts P P a a r r t t D D e e s s c c r r i i p p t t i i o o n n Burner Pilot Kit Main Burner Tube...
  • Page 19: Section Ix: Warranty

    SECTION IX: WARRANTY LIMITED WARRANTY FOR GAS-FIRED WATER HEATER Bock Water Heaters, Inc. 110 S. Dickinson Street Madison, WI 53703 Phone: 608-257-2225 WHAT DOES THIS LIMITED WARRANTY COVER? This limited warranty applies only to the original consumer purchaser. General Defects and Malfunctions: This warranty covers defections and malfunctions in your new water heater for a period of one year from the original installation date.
  • Page 20 INDIRECT, AND WHETHER ARISING IN CONTACT OR TORT. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. Bock Water Heaters, Inc. • 110 South Dickinson Street • Madison, WI 53703 Telephone 608 -257-2225 • Fax 608 -257- 5304 www.bockwaterheaters.com...

Table of Contents