IN-Z64 (Part No. 32319618)
Retrofit kit – Order No. 72910117
IN-Z65 (Part No. 32319762)
Retrofit kit – Order No. 72910180
IN-Z68 Part/Order No. 32320278
Interface parameters, see page 9 (Technical data).
▷ As regards explosion protection, pulse transmit-
ters IN-Z6x are classified as simple electrical
apparatus and must thus not be marked.
Other communication modules
Meters which are marked with
rofitted with communications modules certified in
accordance with 2014/34/EU and which correspond
to the appropriate interface parameters (see page

9 (Technical data)).

Technical data
Diaphragm gas meter BK
Gas type: natural gas, town gas, propane and butane,
as gases of the first to third families pursuant to
DIN EN 437:2003 (DVGW Code of Practice G260).
The following technical data can be found on the
type label/index plate:
max. allowable operating pressure p
measuring range: Q
max. allowable ambient temperature range t
max. allowable gas temperature range t
cyclic volume V
For meters with temperature conversion only:
base gas temperature t
specified centre temperature t
Other technical data:
transitional flow rate Q
max. allowable storage temperature range:
-25 to +60°C
mechanical environment class: M1
▷ Observe installation conditions! See 4 (In-
stallation).
electromagnetic environment class: E2
Supplementary notes:
*
If operated within the gas temperature range, the
measurement error still lies within the required
error limits. If no gas temperature t
on the index plate, the following applies: t
**
The specified centre temperature t
G...E... series and BK-G...B meters is not stated
on the index plate, but can be called up in the
display using the menu.
may only be ret-
max
/Q
min
max
*
g
b
**
sp
 = 0.1 x Q
t
max
is specified
g
 = t
g
of the BK-
sp
Diaphragm gas meters BK with pressure test
point
Pressure test point: 24° olive fitting to EN ISO 8434-1,
L6 x M12 x 1.5-St.
Diaphragm gas meters BK with explosion
protection
For meters of Category 1 which are marked with
, the ambient temperature t
temperature t
gas
between -20°C and +55°C. In this case, the admis-
sible temperatures are to be taken from the ATEX
identification sticker.
The following parameters apply for meters BK-G..M,
BK-G..C, BK-G..MT, BK-G..CT with pulse transmit-
ter IN-Z6x:
IN-Z6, IN-Z6, IN-Z6, IN-Z64, IN-Z65:
U
= 30 V
i
I
= 50 mA
i
P
= 250 mW
i
C
, L
negligible
i
i
IN-Z68:
U
= 8 V
i
I
= 10 mA
i
The following interface parameters apply for
BK-G...A/AT:
U
= 5.5 V
i
I
= 30 mA
i
m
P
= 33 mW
i
C
= 140 µF
i
L
= 0 µH
i
Diaphragm gas meters BK with integrated
"Smart Valve" Vs
Not suitable for highly contaminated gases, e.g.
town gas.
Opening time (from closed to open/released state):
≤ 4 s.
Closing time: ≤ 0.5 s.
Min. operating pressure: 17.5 mbar.
Allowed leakage flow in the customer's piping:
valve released: max. 13 l/h at 35 mbar,
valve closed: max. 5 l/h.
Diaphragm gas meters BK with integrated
valve Ve
Opening time incl. flow rate measurement: < 2 min.
.
Opening and closing times: approx. 5 s
m
(max. 15 s).
Max. operating pressure for valve operation:
100 mbar.
▷ The operating pressure of the gas meter can be
higher if necessary.
Leakage flow (closed): max. 1 l/h up to 100 mbar.